The Clinical Diagnosis of Meniscal Tear is Not Easy. Reliability of Two Clinical Meniscal Tests and Magnetic Resonance Imaging

Author:

Rinonapoli G.1,Carraro A.2,Delcogliano A.3

Affiliation:

1. Orthopaedic Dept, University of Perugia, Perugia, Italy

2. Orthopaedic Area, Villa Maria Cecilia Hospital, Cotignola (RA), Italy

3. Delcogliano A.: Orthopaedic Dept, San Carlo di Nancy Hospital, Rome, Italy

Abstract

Aim: to clarify the reliability of two clinical meniscal tests, McMurray's and Apley's and the MRI imaging, in order to establish how to reduce unjustified arthroscopies. Methods: 102 patients were selected out of 160. All patients were submitted to a triple clinical examination (by a young surgeon and two skilled surgeons), MRI and an arthroscopic procedure. The investigated clinical tests were McMurray's and Apley's test. The positivity or negativity of the tests and MRI were compared to arthroscopic findings. Arthroscopy is considered the gold standard for the diagnosis of meniscal lesions. We measured the length of the meniscal lesions in order to correlate it to the clinical findings. Results: From the clinical examination, we got the following data: McMurray's test: sensitivity 79.7%, specificity 78.5%, accuracy 79.4%, positive likelihood ratio 3.7, negative likelihood ratio 0.2. Apley's test: sensitivity 83.7%, specificity 71.4%, accuracy 80.3%, positive likelihood ratio 2.9, negative likelihood ratio 0.2. The composite assessment is strictly dependent on how the discordance of the two tests is evaluated. The assessment of the clinical tests was done even in relation to medial or lateral meniscal lesion. No statistical difference was found about the length of the meniscal tear. MRI gave the following results: sensitivity 78.3%, specificity 85.7%, accuracy 80.3%. Conclusions: If we use, as diagnostic means, McMurray's and Apley's clinical tests and MRI as imaging procedure, we have an accuracy of about 80%. It is important to keep in mind that it is not possible to have the absolute certainty of make a correct diagnosis in case of meniscal lesions. Patients, too, have to be informed about the risk of a negative arthroscopy.

Publisher

SAGE Publications

Subject

Pharmacology,Immunology,Immunology and Allergy

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3