Comparison of Thermal Infrared and Laser Doppler Imaging in the Assessment of Cutaneous Tissue Perfusion in Scleroderma Patients and Healthy Controls

Author:

Merla A.12,Di Donato L.12,Romani G.L.12,Proietti M.3,Salsano F.3

Affiliation:

1. Department of Clinical Sciences and Bioimaging, G. d'Annunzio University, Chieti

2. ITAB, Institute for Advanced Biomedical Technologies, G. d'Annunzio University Foundation, Chieti

3. Department of Clinical Immunology and Allergy, Sapienza University, Rome, Italy

Abstract

In this study we propose a non-invasive method to calculate blood flow by means of thermal infrared imaging and bio-heat transfer modeling. The method is able to provide high time-resolution series of cutaneous blood flow images with the same spatial resolution of the thermal images. The method was tested against a standard laser Doppler imaging system, which to date is considered the gold standard for non-invasive assessment of cutaneous blood flow, on both healthy subjects and patients suffering from systemic sclerosis (SSc; a pathological condition with microvessel endothelium injury). Twenty healthy subjects and twenty SSc patients simultaneously underwent laser Doppler and thermal imaging of the dorsum of the hand. A linear correlation between perfusion values obtained with the two methods was found for the healthy control group (R = 0.85, Pearson Product Moment Correlation). A significant correlation was not observed for the SSc patient group. The results of this study suggest that combined laser Doppler, thermal imaging and bio-heat transfer modeling could effectively discriminate between healthy vs. impaired conditions of the cutaneous tissue thermal properties and cutaneous vasculature. Such method, in addition to providing a potential effective imaging-based tool for a variety of biomedical and clinical applications ranging from diagnostics to treatment follow-up, may help the understanding of the morphological and functional impairment secondary to the disease. The thermal imaging-based method provided faster and better time-resolved imaging of cutaneous perfusion than standard laser Doppler techniques as the thermal cameras can provide up to 100 complete 524×524 pixel images per second, thus allowing real time monitoring of tissue perfusion rates.

Publisher

SAGE Publications

Subject

Pharmacology,Immunology,Immunology and Allergy

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3