Abstract

Background: Does initiation of a continuous glucose monitor (CGM) or insulin pump lower health care utilization and/or costs? Methods: Distinct cohorts of people with type 1 diabetes (T1D) or type 2 diabetes (T2D) using a blood glucose monitor (BGM), CGM, pump, or CGM with pump were identified from a large claims database. Patients ≥40 years old with 12 months of continuous enrollment before and after the device start date qualified for the study. Outcomes included one-year medical utilization and costs (minus device) for events such as hospitalizations and office visits. Generalized linear models were fitted, controlling for numerous baseline covariates. The Holm method corrected for the multiplicity of hypotheses tested. Results: Of the 8235 total patients, the BGM control group was the largest, had the lowest percentage of patients with T1D, and was significantly different from the device groups in most baseline categories. Formally, only two comparisons were statistically significant: Compared with BGM, the pump cohort had greater adjusted first-year total medical and office visit costs. Other secondary outcomes such as days hospitalized, emergency department visits and labs, favored pump. Most endpoints were favorable for CGM. Results for CGM with pump generally were intermediate between CGM and pump alone. Conclusions: During a one-year follow-up, unadjusted medical costs of both CGM and pump appear lower than BGM, but multivariable modeling yielded adjusted savings only for CGM use. Economic benefits might be observable sooner for CGMs than for pumps. Generalized linear models fitted to health care utilization event rates produced favorable results for both CGM and pump.

Funder

eli lilly and company

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Addressing disparities in technology use among patients with type 1 diabetes: a review;Current Opinion in Endocrinology, Diabetes & Obesity;2023-10-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3