A Simulation Study to Assess the Effect of Analytic Error on Neonatal Glucose Measurements Using the Canadian Pediatric Society Position Statement Action Thresholds

Author:

Inman Mark1,Parker Kayla1,Strueby Lannae1,Lyon Andrew W.2ORCID,Lyon Martha E.2ORCID

Affiliation:

1. Department of Pediatrics, University of Saskatchewan, Saskatoon, SK, Canada

2. Division of Clinical Biochemistry, Department of Pathology and Laboratory Medicine, Saskatchewan Health Authority, Royal University Hospital, Saskatoon, SK, Canada

Abstract

Background: The Canadian Pediatric Society (CPS) has endorsed an algorithm for the screening and immediate management of babies at risk of neonatal hypoglycemia that provides time-dependent glucose concentration action thresholds. The objective of this study was to evaluate the impact of glucose analytic error (bias and imprecision) on the misclassification of glucose meter results from a neonatal intensive care unit (NICU) using the CPS guidelines. Methods: A simulation dataset of true glucose values ( N = 100 000) was derived by finite mixture model analysis of NICU glucose data ( N = 23 749). Bias and imprecision were added to create measured glucose values. The percentages of measured glucose values that were misclassified at CPS action thresholds were determined by Monte Carlo simulation. Results: Measurement biases ranging from −20 to +20 mg/dL combined with coefficients of variation 0% to 20% were evaluated to predict misclassification rates at 32, 36, and 47 mg/dL. The models demonstrated low risk of false normoglycemia—at 5% CV and +10 mg/dL bias: 0.8% to 5% misclassification at the 32 and 47 mg/dL thresholds due to bias. The models demonstrated risk of false hypoglycemia—at 5% CV and −10 mg/dL bias: 3% to 12.5% misclassification at 32 and 47 mg/dL thresholds due to both bias and imprecision. Conclusion: Using CPS action thresholds, the simulation model predicted the proportion of neonates at risk of inappropriate clinical action—both of omission or “failure to treat” and commission or “overtreatment” in response to NICU glucose meter results at specific bias and imprecision values.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3