Eliminating the Blood: Ongoing Outbreaks of Hepatitis B Virus Infection and the Need for Innovative Glucose Monitoring Technologies

Author:

Thompson Nicola D.1,Perz Joseph F.2

Affiliation:

1. Epidemiology and Surveillance Branch, Division of Viral Hepatitis, Centers for Disease Control and Prevention, Atlanta, Georgia

2. Prevention and Response Branch, Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia

Abstract

Background: As part of routine diabetes care, capillary blood is typically sampled using a finger-stick device and then tested using a handheld blood glucose meter. In settings where multiple persons require assistance with blood glucose monitoring, opportunities for bloodborne pathogen transmission may exist. Methods: Reports of hepatitis B virus (HBV) infection outbreaks in the United States that have been attributed to blood glucose monitoring practices were reviewed and summarized. Results: Since 1990, state and local health departments investigated 18 HBV infection outbreaks, 15 (83%) in the past 10 years, that were associated with the improper use of blood glucose monitoring equipment. At least 147 persons acquired HBV infection during these outbreaks, 6 (4.1%) of whom died from complications of acute HBV infection. Outbreaks appear to have become more frequent in the past decade, primarily affecting long-term care residents with diabetes. Each outbreak was attributed to glucose monitoring practices that exposed HBV-susceptible persons to blood-contaminated equipment that was previously used on HBV-infected persons. The predominant unsafe practices were the use of spring-loaded finger-stick devices on multiple persons and the sharing of blood glucose testing meters without cleaning and disinfection between uses. Conclusion: Hepatitis B virus infection outbreaks associated with blood glucose monitoring have occurred with increasing regularity in the Unites States and may represent a growing but under-recognized problem. Advances in technology, such as the development of blood glucose testing meters that can withstand frequent disinfection and noninvasive glucose monitoring methods, will likely prove useful in improving patient safety.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 57 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3