Safety of Insulin Lispro and a Biosimilar Insulin Lispro When Administered Through an Insulin Pump

Author:

Thrasher James1,Surks Howard2,Nowotny Irene3,Pierre Suzanne4,Rotthaeuser Baerbel3,Wernicke-Panten Karin3,Garg Satish5

Affiliation:

1. Medical Investigations, Inc, Little Rock, AR, USA

2. Sanofi, Bridgewater, NJ, USA

3. Sanofi-Aventis Deutschland GmbH, Frankfurt, Germany

4. Sanofi, Paris, France

5. Barbara Davis Center for Diabetes, University of Colorado Denver, Aurora, CO, USA

Abstract

Background: SAR342434 (U100; SAR-Lis; insulin lispro) is a biosimilar/follow-on to insulin lispro (U100; Ly-Lis). Similar pharmacokinetics/pharmacodynamics between the two products has been demonstrated in a hyperinsulinemic euglycemic clamp study. The current study evaluated the safety of SAR-Lis and Ly-Lis when administered by continuous subcutaneous insulin infusion (CSII; insulin pumps). Methods: This was a randomized, open-label, 2 × 4-week, two-arm crossover study in 27 patients with type 1 diabetes mellitus (NCT02603510). The main outcome was the incidence of infusion set occlusions (ISOs), defined as failure to correct hyperglycemia (plasma glucose ≥≥ 300 mg/dl) by 50 mg/dl within 60 minutes by insulin bolus via the pump. Secondary outcomes included intervals between infusion set changes, treatment-emergent adverse events (TEAEs) including infusion site, hypersensitivity reactions and hypoglycemic events, and safety. Results: The number of patients reporting at least one ISO was small: 6/25 patients on SAR-Lis reported 14 ISOs and 4/27 on Ly-Lis reported nine ISOs. The estimated difference in ISO risk for SAR-Lis versus Ly-Lis was 7.9% (95% CI, –1.90 to 17.73). Mean interval between infusion set changes for any reason was similar with SAR-Lis (3.09 days) and Ly-Lis (2.95 days). The event rate (events/patient-month) of any hypoglycemia was similar with SAR-Lis (7.15) and Ly-Lis (7.98), as was the percentage of patients who experienced any TEAE (12.0% and 14.8%). Conclusion: Both SAR-Lis and Ly-Lis were well tolerated by patients using insulin pumps. The results do not suggest a clinically significant difference in the risk of ISO between SAR-Lis and Ly-Lis when used in CSII.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3