Automated Self-Adjusting Subcutaneous Insulin Algorithm for Patients NPO or on TPN or Enteral Feedings

Author:

Patzek Sophie1ORCID,MacMaster Heidemarie W.2,Rov-Ikpah Esther3,San Luis Craig4,Johnson Craig5,Juttukonda Venkateswarlu6,Rushakoff Robert J.1

Affiliation:

1. Division of Endocrinology and Metabolism, University of California, San Francisco, CA, USA

2. Department of Pharmacy, Lahey Hospital and Medical Center, Burlington, MA, USA

3. Institute for Nursing Excellence, University of California, San Francisco, CA, USA

4. Department of Clinical Systems, University of California, San Francisco, CA, USA

5. Department of Health Informatics, University of California, San Francisco, CA, USA

6. Department of Clinical Applications & Analytics, University of California, San Francisco, CA, USA

Abstract

Background: Perioperative diabetes patients are often treated with sliding-scale insulin, despite a lack of evidence to support therapeutic effectiveness. We introduced an automated subcutaneous insulin algorithm (SQIA) to improve glycemic control in these patients while maintaining the simplicity of a q4 hour adjustable sliding-scale insulin order set. Methods: In this pilot study, we implemented a fully programmed, self-adjusting SQIA as part of a structured order set in the electronic medical record for adult patients who are nil per os, or on continuous enteral tube feedings or total parenteral nutrition. The nurse only enters the current glucose in the Medication Administration Record, and then the calculated dose is shown. The new dose is based on previous dose, and current and previous glucoses. The SQIA titrates the glucose to 120-180 mg/dL. For this pilot, this order set was utilized for complex perioperative oncologic patients. Results: The median duration on the SQIA was 58 hours. Glucoses at titration initiation were highest at 206 ± 63 mg/dL, and came down to 156 ± 29 mg/dL by 72 hours. The majority of measured glucoses (66.8%, n = 647) were maintained between 80 and 180 mg/dL. There were no glucoses lower than 60 mg/dL, and only 0.3% (n = 3) were below 70 mg/dL. There was a low rate of errors (1%). Conclusions: A simple automated SQIA can be used to titrate insulin to meet the changing metabolic requirements of individuals perioperatively and maintain glucose within the target range for these hospitalized patients.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Diabetes and Enteral Nutrition in the Hospital Setting;Diabetes Management in Hospitalized Patients;2023