Pilot Study for Assessment of Optimal Frequency for Changing Catheters in Insulin Pump Therapy—Trouble Starts on Day 3

Author:

Schmid Volkmar1,Hohberg Cloth2,Borchert Marcus1,Forst Thomas2,Pfützner Andreas2

Affiliation:

1. IKFE—CRO, Mainz, Germany

2. IKFE—Institute for Clinical Research and Development, Mainz, Germany

Abstract

Background: Continuous subcutaneous insulin infusion (CSII) by means of insulin pump devices is considered to be one of the most optimal therapies to achieve treatment targets in patients with diabetes mellitus. In CSII, the insulin is delivered through Teflon catheters or steel needle infusion sets, which need to be renewed on a regular basis. This pilot study was performed to investigate the optimal change frequency in daily practice and to explore potential problems that may occur when the sets are used for a more prolonged time than the recommended up to 72 hours of usage (Teflon catheters). Method: Twelve patients with type 1 diabetes participated in the trial [age (mean ± STD): 40.3 ± 12.6 years, body mass index: 26.2 ± 3.3 kg/m2, hemoglobin A1c: 6.7 ± 0.6%]. They were asked to wear their infusion set (Comfort™ or Silhouette®) for increasing periods of 1, 2, 3, 4, and 5 days. After each use, patients completed standardized questionnaires regarding technical and medical issues associated with infusion set use. A health care professional investigated the infusion sites and infusion sets and completed an “infusion set inspection” questionnaire. Blood glucose was measured and recorded to assess a potential Influence of duration of catheter use on glycemic control. Results: Infusion set and injection site problems (itching, bruising, swelling, and pain) started to occur in measurable amounts on the 3rd day of catheter use, and about 40% of patients reported significant issues when using a catheter for 5 days. In parallel, there was a consistent increase in mean daily blood glucose levels that correlated with the number of days of catheter use (e.g., day 1: 7. 5 ± 3.8 mmol/liter, day 3: 8.4 ± 4.2 mmol/liter, day 5: 9.0 ± 4.0 mmol/liter, day 7: 11.6 ± 2.2 mmol/liter, p < 0.05 vs day 1). Conclusions: Using the catheters for 2 days resulted in a safe and well-tolerated therapy. Clinically relevant adverse events started to occur during the 3rd day and their incidence increased constantly with longer use. This was associated with undesired changes in mean glycemic control. Data support the recommendation by the drug and device manufacturers that insulin pump catheters should only be used for 48–72 hours to avoid adverse events and potential metabolic deterioration.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3