Advancing the Use of CGM Devices in a Non-ICU Setting

Author:

Wang Meng1,Singh Lakshmi G.2,Spanakis Elias K.23ORCID

Affiliation:

1. Division of Hospital Medicine, Baltimore Veterans Affairs Medical Center, Baltimore, MD, USA

2. Division of Diabetes and Endocrinology, Baltimore Veterans Affairs Medical Center, Baltimore, MD, USA

3. Division of Endocrinology, Diabetes and Nutrition, University of Maryland School of Medicine, Baltimore, MD, USA

Abstract

Improvements in glycemic control using continuous glucose monitoring (CGM) systems have been demonstrated in the outpatient setting. Among hospitalized patients the use of CGM is largely investigational, particularly in the non-ICU setting. Although there is no commercially available closed-loop system, it has recently been evaluated in the non–critical care setting. Both CGMs and closed-loop systems may lead to improved glycemic control, decreased length of stay, reduced risk of adverse events related to severe hypoglycemia or hyperglycemia. Limitations of inpatient use of CGM and closed-loop systems include lack of FDA approvals, inexperience with this technology, and costs related to supplies. Significant investment may be necessary for hospital staff training and for development of infrastructure to support inpatient use. Additional limitations for CGM systems includes potential inaccuracy of interstitial glucose measurements due to medication interferences, sensor lag, or sensor drift. Limitations for closed-loop systems also includes need for routine monitoring to detect infusion site issues as well as monitoring to ensure adequate insulin supply in reservoir to avoid abrupt cessation of insulin infusion leading to severe hyperglycemia. Hospital staff must be familiar with trouble-shooting and conversion to alternative mode of insulin delivery in the event of insulin pump malfunction. Given these complexities, implementation of closed-loop systems may require involvement of an endocrinology team, limiting widespread adoption. This article reviews current state of CGM and closed-loop system use in the non-ICU setting, available literature, advantages and limitations, as well as suggestions for future CGM design, specifically for the inpatient setting.

Funder

VA MERIT award

Publisher

SAGE Publications

Subject

Biomedical Engineering,Bioengineering,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3