Are adverse events during surgery for benign prostatic hyperplasia device related? A review of the MAUDE database

Author:

Heidenberg Daniel J1ORCID,Nethery Ethan2,Wymer Kevin M1,Judge Nathanael3,Cheney Scott M1,Stern Karen L1,Humphreys Mitchell R1

Affiliation:

1. Department of Urology, Mayo Clinic, Phoenix, AZ, USA

2. Virginia Tech Carilion School of Medicine and Research Institute, Roanoke, VA, USA

3. Michigan Technological University, Houghton, MI, USA

Abstract

Purpose: The Manufacturer and User Facility Device Experience database contains anonymous, voluntary medical device reports. A review of device-related adverse events associated with Benign Prostatic Hyperplasia surgeries was completed. The objective was to evaluate the occurrence and contributing factors to clinically significant complications in a cohort of patients electing to undergo surgical intervention for Benign Prostatic Hyperplasia. Methods: The Manufacturer and User Facility Device Experience database was queried for “Aquablation, Greenlight Laser, Holmium Laser, Morcellator, Water Vapor Thermal Therapy, Loop Resection, and Prostatic Urethral Lift” from 2018 through 2021. A complication classification system (Level I–IV) based on the Clavien-Dindo system was used to categorize events. These events were then correlated with procedural technology malfunctions and classified as “device related” and “non-device related.” Chi squared analysis was performed to identify associations between procedural technology and complication classification distribution. Results: A total of 873 adverse events were identified. The adverse events were classified into level I (minimal harm) versus levels II–IV (clinically significant). Aquablation ( p < 0.017) and Water Vapor Thermal Therapy ( p < 0.012) were associated with a higher proportion of reports with Level II-IV complications compared with other procedure types. Level II-IV complications were not associated with a reported device related malfunction. Conclusions: Aquablation and water vapor thermal therapy demonstrated noteworthy clinically significant complications which were not driven by device-related malfunctions.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3