Atrial fibrillation influences automatic oscillometric ankle-brachial index measurement

Author:

Dąbrowski Michał1,Lewandowski Jacek1,Szmigielski Cezary1,Siński Maciej1

Affiliation:

1. Department of Internal Medicine, Hypertension and Vascular Diseases, Medical University of Warsaw, Warsaw, Poland

Abstract

IntroductionRepeated measurements of ankle-brachial index (ABI) using Doppler method were shown to be accurate during atrial fibrillation. Oscillometric devices are effective in ABI measurement, but their accuracy during atrial fibrillation is unknown. The purpose of the study was to investigate whether atrial fibrillation influences ABI obtained with the automatic oscillometric method.Material and methodsNinety-nine patients with atrial fibrillation (mean age: 66.6 +(SD = 11) years, M/F  63/36) who underwent electrical cardioversion were investigated (198 lower extremities). The ABI measurements using oscillometric and Doppler methods were performed on both lower extremities before and after procedure.ResultsThe ABI measured using the oscillometric method on both lower limbs did not change after cardioversion (1.21 (IQR: 1.13-1.27) vs. 1.22 (IQR: 1.14-1.26), p = 0.664, respectively). The ABI measured before and after cardioversion using Doppler and oscillometric methods showed a significant difference (1.14 (IQR: 1.07-1.22) vs. 1.21 (IQR 1.13-1.27), p < 0.001 and 1.18 (IQR: 1.09-1.13) vs. 1.22 (IQR: 1.14-1.26), p < 0.001 respectively). Both methods showed a weak correlation before (r = 0.35, p < 0.001) and no correlation after cardioversion (r = 0.12, p = 0.07). The Bland-Altman plot showed poor agreement between measurements performed with the Doppler and oscillometric methods in sinus rhythm and during atrial fibrillation.ConclusionsThe automated oscillometric method of ABI measurements should not replace the reference Doppler method in patients with atrial fibrillation. More research related to the oscillometric measurements is needed in subjects with peripheral artery disease and atrial fibrillation.

Publisher

Termedia Sp. z.o.o.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3