Accuracy of Impression Material During COVID-19 after Sterilization- In vitro Study

Author:

Alhaddad Abdulrahman JafarORCID

Abstract

Aims: The goal of this research is to assess the effect of steam autoclave sterilization due to the impact of Covid-19 on the accuracy of the elastomer impression materials. Study Design: In vitro study. Place and Duration of Study: Department of oral and Maxillofacial Prosthodontics, King Abdul-Aziz University, Jeddah; Saudi Arabia, between June 2021 and November 2021. Methodology: The following materials were used in this study: fully dentate master cast, metal trays, elastomer impression material (addition silicon), type IV stone. Forte impressions made using the metal tray and elastomer impression materials. The impressions were separated equally into two groups: Control group (C.G), untreated impressions. Sterilized group (S.G): Impressions were sterilized by using the steam autoclave. To make stone castings for each group, they were poured with type IV stone. The traveling microscope was used to evaluate the impression material's dimensional accuracy and detail reproduction with and without autoclave sterilization. Results: The cross-arch distance (X) of the master model was measured (41.29 mm), While the cross arch distance (X) in the control group (C.G) of the untreated impressions  had a mean and standard deviation  of 41.492 ± 0.150 mm. In the tested group  (S.G) : the sterilized impression, we found the cross-arch distance (X) had a mean and standard deviation of 41.628 ± 0.223 mm. The master model's Anteroposterior distance (A-P) was measured (21.12 mm). For the control group  (C.G) : we found the mean and standard deviation value reading of the A-P distance were 20.899 ± 0.79 mm. For (S.G) group: we found the mean and standard deviation reading of the A-P distance were 19.992± 0.482 mm. Conclusion: Steam autoclave sterilization of the elastomer impression material should be considered carefully, especially when fabricating fixed partial dentures. If the impression material is to be used in making diagnostic castings, conventional steam autoclave sterilization of the elastomers impression material may be sufficient for patients.

Publisher

Sciencedomain International

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3