Functional Outcome of Shaft of Humerus Fractures Managed Surgically by Dynamic Compression Plating Technique
-
Published:2021-11-12
Issue:
Volume:
Page:101-104
-
ISSN:2456-9119
-
Container-title:Journal of Pharmaceutical Research International
-
language:
-
Short-container-title:JPRI
Abstract
The study analyzed 20 cases of fracture shaft of hummers treated with Dynamic Compression Plate. There was a male preponderance in our study 17 (85%). Almost Also 13% of patients treated by functional bracing end up with cosmetically unacceptable angulation of>15%, whereas all operative procedures achieve good alignment of the fractured bone was observed. The rate of union in Plate osteosynthesis is 93% and the time of union is 16 - 20 weeks, and more than 90% united in 18 weeks and 7% went for non union.
Publisher
Sciencedomain International