Dried blood spots as a sampling technique for the quantitative determination of guanfacine in clinical studies

Author:

Li Yuanyuan1,Henion Jack,Abbott Richard2,Wang Phillip3

Affiliation:

1. Advion BioServices, Inc., Ithaca, NY, USA

2. Shire Pharmaceutical Development Ltd., Basingstoke, UK

3. Shire Development, Inc., Wayne, PA, USA

Abstract

Background: Dried blood spot (DBS) technology was evaluated for the quantitative determination of guanfacine in human blood in clinical studies. A very sensitive DBS assay has been developed using HPLC coupled with an AB Sciex 5500 QTRAP® (Applied Biosystems/MDS Sciex, ON, Canada) MS system (LC–MS/MS) with a linear calibration range of 0.05 to 25 ng/ml. High-resolution MS using an Exactive Orbitrap® (ThermoFisher, LLC., CA, USA) was compared with the QTRAP using extracted exact mass ion current profiles for guanfacine and its stable-isotope-incorporated internal standard. The sample preparation employed liquid–liquid extraction with methyl t-butyl ether of 5 mm punched DBS card disks, followed by reversed-phase HPLC separation coupled with either MS/MS or high-resolution MS. Routine experiments were performed to establish the robustness of the DBS assay, including precision, accuracy, linearity, selectivity, sensitivity and long-term stability of up to 76 days. In addition, several factors that potentially affect quantitation were investigated, including blood volume for DBS spotting, punch size and punch location. Results: A sensitive research assay with a LLOQ of 0.05 ng/ml was developed and subjected to several components of a method validation common to a regulated bioanalysis procedure employing DBS. This method development and partial validation study determined that spot volume, punch size or punch location do not affect assay accuracy and precision. The DBS approach was successfully applied to a clinical study (a Phase I, randomized, double-blind, placebo-controlled, crossover study to assess the effect of varying multiple oral doses of guanfacine on the pharmacokinetic, pharmacodynamic, safety, and tolerability profiles in healthy adult subjects). The pharmacokinetic profiles for 12 volunteers generated from the DBS assay and from a previously validated plasma assay were compared and were found to be comparable. DBS incurred samples collected from finger prick blood and directly applied to the DBS cards were also analyzed for comparison. Conclusion: From a bioanalytical perspective, DBS sample collection and analysis is a potentially viable alternative for guanfacine determination in clinical studies, utilizing approximately 100 µl of blood per subject profile compared with a few millilitres of blood drawn for conventional plasma bioanalysis.

Publisher

Future Science Ltd

Subject

Medical Laboratory Technology,Clinical Biochemistry,General Pharmacology, Toxicology and Pharmaceutics,General Medicine,Analytical Chemistry

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3