Determination of six pterins in urine by LC–MS/MS

Author:

Allegri Gabriella1,Costa Netto Heleno José Bezerra2,Ferreira Gomes Luiz Nelson Lopes2,Costa de Oliveira Maria Lúcia2,Scalco Fernanda Bertão2,de Aquino Neto Francisco Radler3

Affiliation:

1. Laboratório de Erros Inatos do Metabolismo (LABEIM/LADETEC), Instituto de Química, Universidade Federal do Rio de Janeiro, Av. Athos da Silveira Ramos, 149 Bl. A, s/ 536-C, Cidade Universitária Rio de Janeiro, 21941–909, Brasil.

2. Laboratório de Erros Inatos do Metabolismo (LABEIM/LADETEC), Instituto de Química, Universidade Federal do Rio de Janeiro, Av. Athos da Silveira Ramos, 149 Bl. A, s/ 536-C, Cidade Universitária Rio de Janeiro, 21941–909, Brasil

3. Laboratório de Desenvolvimento de Tecnologias (LADETEC), Instituto de Química, Universidade Federal do Rio de Janeiro, Av. Athos da Silveira Ramos, 149 Bl. A, s/ 607, Cidade Universitária Rio de Janeiro, 21941–909, Brasil

Abstract

Background: The present work describes an analytical method for urinary pterins by LC–MS/MS, with emphasis on the separation of 6- and 7-positional isomers of bio- and neopterins. Results: Urine sample preparation consisted of oxidation by MnO2, filtration and direct dilution in the mobile phase. The method was validated in urine spiked at five concentration levels with true triplicates of each level. Separation of the pterins, including the positional isomers, was achieved by employing a LUNA amino column. Six pterins were quantified (pterin, isoxanthopterin, 6-biopterin, 7-biopterin, 6-neopterin, 7-neopterin) and a linear behavior was observed; LOD varied from 7 to 360 pg/ml and correlation coefficients above 0.98 were obtained for all pterins. In addition, pterin levels were evaluated in 41 urine samples of healthy subjects, in ten urine samples of patients with classical phenylketonuria (PKU) and in one with atypical PKU. Conclusion: The proposed method allowed to identify, separate and quantify six pterins in urine, using a simple and rapid sample preparation. The atypical PKU was unequivocally differentiated from the classical form, demonstrating that this method could be very useful for characterization and follow-up of diseases.

Publisher

Future Science Ltd

Subject

Medical Laboratory Technology,Clinical Biochemistry,General Pharmacology, Toxicology and Pharmaceutics,General Medicine,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3