Comparison of the quantification of a therapeutic protein using nominal and accurate mass MS/MS

Author:

Plumb Robert S1,Fujimoto Gordon2,Mather Joanne3,Potts Warren B3,Rainville Paul D34,Ellor Nicholas J2,Evans Christopher5,Kehler Jonathan R5,Szapacs Matthew E5

Affiliation:

1. Department of Surgery & Cancer, Imperial College, South Kensington, London, SW7 2AZ, UK.

2. Waters Corporation, 100 Cummings Centre, Beverly, MA, USA

3. Waters Corporation, 34 Maple St, Milford, MA, USA

4. Micro Separations Group, King’s College London, 100 Stamford St, London, UK

5. DMPK Department, GlaxoSmithKline, Upper Merion, PA, USA

Abstract

Background: The quantification of proteins and peptides in in vivo samples is a critical part of supporting the drug development process for biotherapeutics. LC–MS/MS using tandem quadrupole mass spectrometers is well established as the technology of choice for the quantification of small-molecule drugs and their metabolites in biological fluid. The application of accurate mass MS for quantification in a DMPK environment has attracted considerable interest in recent years. Materials & Methods: In this article we describe and compare the application of LC–high-resolution MS and LC–selected reaction monitoring (SRM) for the quantification of a therapeutics proteins. Results: The accurate mass instrumentation showed acceptable linearity and sensitivity to quantify the protein therapeutic to the level of 10 ng/ml. The accurate mass instrument was operated in accurate mass SRM using high resolution (SRM-HR), the assay was demonstrated to be linear over three orders of magnitude. By narrowing the mass window from 100 mDa to 40 mDa and then to 20 mDa the assay specificity was significantly improved, hence increasing the S/N and improving the assay sensitivity. Conclusion: The high-resolution instrument was demonstrated to be reproducible over the course of the assay. The accurate mass method sensitivity was determined to be within one order of magnitude of that obtained with a tandem quadrupole MS/MS assay.

Publisher

Future Science Ltd

Subject

Medical Laboratory Technology,Clinical Biochemistry,General Pharmacology, Toxicology and Pharmaceutics,General Medicine,Analytical Chemistry

Reference29 articles.

1. Trends in the exploitation of novel drug targets

2. The productivity crisis in pharmaceutical R&D

3. 2009 FDA drug approvals

4. TaizinB. Medicine in Development Biotechnology, Report 2006.Pharmaceutical Research and Manufacturers of America1–51 (2006).

5. The safety and side effects of monoclonal antibodies

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3