Ultrasonographic Evaluation of the Effect of Osteopathic Manipulative Treatment on Sacral Base Asymmetry

Author:

Snider Karen T.,Redman Crystal L.,Edwards Christopher R.,Bhatia Shalini,Kondrashova Tatyana

Abstract

Abstract Context Patients with low back pain (LBP) may receive osteopathic manipulative treatment (OMT) to resolve or manage their pain. The indication for OMT for patients with LBP is the presence of somatic dysfunction, diagnosed using palpatory examination. Because palpatory findings commonly have poor interexaminer reliability, the current study used ultrasonography (US) to establish pre-OMT and post-OMT musculoskeletal measurements of relative asymmetry between pelvic and sacral bony landmarks. Objective To document objective musculoskeletal changes that occur in response to OMT using US and to compare palpatory assessment of landmark asymmetry with US assessment. Methods Sixty men and women aged 20 to 55 years with at least 1 episode of LBP in the past 2 weeks were assigned to a seated control, walking control, or OMT group (20 participants per group). Participants received an initial, bilateral US measurement of the skin to posterior superior iliac spine (SPSIS), skin to sacral base position (SBP), and sacral sulcus depth (SSD). Participants in seated control and OMT groups received a palpatory assessment of SBP and SSD prior to initial US assessment. After assessment, the seated control group sat in a waiting room for 30 minutes, the walking control group walked for 5 minutes, and the OMT group received OMT to address sacral base asymmetry using predominantly direct techniques for a maximum of 20 minutes. Participants then received a second US assessment of the same structures. Results Body mass index (BMI) was correlated with SPSIS (r=0.5, P=.001) and SBP (r=0.6, P<.001). More participants in seated control (75%) and OMT (65%) groups had an increase in asymmetry from first to second US assessment for SPSIS compared with participants in the walking control group (35%, P=.05). No significant differences were found between groups for absolute asymmetry or total change in asymmetry (all P>.10). The κ was −0.1 (95% CI, −0.2 to 0.03) for SBP and −0.01 (95% CI, −0.1 to 0.1) for SSD. Conclusion Musculoskeletal changes in SPSIS and SBP measurements related to OMT could not be readily identified using US. The SPSIS and SBP measurements were dependent on BMI, which may have affected the accuracy of US to detect small changes in asymmetry. Qualitative palpatory assessments did not correlate with US measurements. Further study is needed to identify US measurements that demonstrate change with OMT. (ClinicalTrials.gov number NCT02820701)

Publisher

Walter de Gruyter GmbH

Subject

Complementary and alternative medicine,Complementary and Manual Therapy

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3