Effect of Hydration on Doppler Velocity of Renal Arteries

Author:

Lee Juhyun,Gao Jing

Abstract

Abstract Context Doppler sonography is a noninvasive method to evaluate the hemodynamic status of the kidney, and its parameters are used as direct and indirect predictors of certain parenchyma and renovascular diseases. However, the effect of hydration on kidney hemodynamics has not been explored via Doppler sonography. Objective To examine differences in arterial Doppler velocities of normal adult kidney before and after hydration. Methods A total of 60 native kidneys in 30 normal adult participants (mean age, 26 years) were assessed using Doppler sonography. Quantitative ultrasound Doppler parameters of peak systolic velocity (PSV), end diastolic velocity (EDV), and resistive index (RI) of the main renal artery and the intrarenal (interlobar) arteries were measured immediately before and 1 hour after ingestion of 500 mL of water. We tested differences in Doppler parameters before and after hydration using a paired t test, analyzed the correlation of the increase in PSV to the increase in EDV after hydration using Pearson correlation coefficient (PCC), and examined intraobserver reliability using intraclass correlation coefficient (ICC). Results Statistical analyses revealed that the differences in PSV and EDV values before and after hydration at the main renal artery and interlobar arteries of the kidney were significant (P<.001), whereas the RI at the main renal artery and interlobar arteries were not (P>.05). PCC for the correlation of the increase in PSV to the increase in EDV was greater than 0.80. ICC for intraobserver repeatability in performing kidney Doppler sonography was 0.92. Conclusion Our results suggest that Doppler sonography is able to demonstrate changes in kidney hemodynamics within 1 hour after hydration. The normal kidney reflects proportional increases in PSV and EDV at the main renal artery and interlobar arteries, while maintaining vascular resistance. Doppler flow velocities of renal arteries can be considered as noninvasive quantitative markers for evaluating the response of kidney hemodynamics to hydration.

Publisher

Walter de Gruyter GmbH

Subject

Complementary and alternative medicine,Complementary and Manual Therapy

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3