Author:
Ali Obed Majeed,Mustafa Ahmed Nawfal
Abstract
In this paper, we will attempt to study a fundamental problem, namely, how gas stations operate worse as the outside temperature rises and production decreases. This examination focused on the gas generator made at the Al-Qayyarah gas station. Based on the data from the station's fourth unit, it was discovered that the two factors that affect the compressor's theoretical efficiency, air temperature entering the device, and compression ratio, are strongly correlated. season is larger than summer because more concentrated energy is generated during the winter, reaching 107.5 MW, whilst concentrated energy production in the summer does not go over 85.8 MW, Due to the cold temperatures, efficiency in the winter was only 29%, while in the summer it was 27.2%.
Reference28 articles.
1. A. Kumar, A. Singhania, A. K. Sharma, R. Roy, and B. K. Mandal, “Thermodynamic Analysis of Gas Turbine Power Plant,” Int. J. Innov. Res. Eng. Manag., no. 3, pp. 648–654, 2017, doi: 10.21276/ijirem.2017.4.3.2.
2. M. M. Rahman, T. K. Ibrahim, and A. N. Abdalla, “Thermodynamic performance analysis of gas-turbine power-plant,” Int. J. Phys. Sci., vol. 6, no. 14, pp. 3539–3550, 2011, doi: 10.5897/IJPS11.272.
3. W. H. A. Razzaq, “Studying the Effects of Using Different Kinds of Fuel,” J. Tech., vol. Volume 22, no. Issue 3, p. Pages A1-A19, 2009.
4. M. Huth and A. Heilos, Fuel flexibility in gas turbine systems: Impact on burner design and performance. Woodhead Publishing Limited, 2013.
5. K. Döbbeling, T. Meeuwissen, M. Zajadatz, and P. Flohr, “Fuel flexibility of the alstom GT13E2 medium sized gas turbine,” Proc. ASME Turbo Expo, vol. 3, no. PART B, pp. 719–725, 2008, doi: 10.1115/GT2008-50950.