Long-Term Results of Excimer Laser Surface Ablation with Smoothing for High Myopia

Author:

Vinciguerra Paolo,Torres Ingrid,Sergio Adriana,Legrottaglie Emanuela F.,Camesasca Fabrizio I.

Abstract

Purpose: To evaluate long-term refractive, aberrometric and anatomical results of surface ablation plus corneal PTK-style smoothing for myopia greater than –7.00 D. Methods: One-hundred-and-fourteen eyes of 69 patients (mean age: 37.7 ± 8.3 years) underwent PRK with the NIDEK EC-5000 excimer laser (NIDEK Co. Ltd., Gamagori, Japan) using multiple optical zones ranging in diameter from 4.89 mm to 7.0 mm, and transition zones (TZ) that were at least 3 mm wider than the optical zones (OZ). A cross-cylinder technique was used for treating astigmatism greater than 0.50 D. All eyes underwent a phototherapeutic keratectomy (PTK) smoothing technique using masking fluid. The Student’s t-test was used to determine a statistically significant change after surgery. A p value less than 0.05 was considered statistically significant. Results: Preoperative corrected distance visual acuity (CDVA) was 0.88 ± 0.16 with –9.53 ± 1.18 D cycloplegic spherical equivalent (SE). Preoperative corneal pachymetry was 560.4 ± 30.1 µ. Three years after surgery uncorrected visual acuity (UCVA) was 0.79 ± 0.26, CDVA was 0.92 ± 0.19 with –0.56 ± 0.90 D SE. Mean corneal haze was highest 1 month after surgery (0.58 ± 0.35), then progressively decreased to 0.11 ± 0.32 by 3 months postoperatively. Following year one, refraction and corneal curvature remained stable. There were no cases of keractasia to date. There was no hyperopic induction due to PTK. Two eyes required retreatment due to undercorrection. Total wavefront error did not change significantly, while astigmatism decreased and coma increased (both with p< 0.001). Conclusion: Surface ablation for the treatment of high myopia using PTK smoothing with a masking fluid was safe and effective. Wide optical and transition zones prevented induction of spherical aberration and the incorporation of the smoothing technique created a regular corneal surface with regular healing and trace to no haze after surgery.

Publisher

Savvy Science Publisher

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3