1. (7-0) where 1, is the normal incident spectral flux. The albedo, and phase function,ii[e), are obtained
2. nAl = nA2 - 0.025 (AI- 12) (28)
3. Solutions to the six equations [Eqs. (21) through (24). (27) and (28)l were obtained numerically by a direct search method. The range of values searched for were: d32. 0.1 to 2 um; n, 1.40 to 1.85: and k, I x 10-5 to 2 x 10-2. Calculated values of TI' and 0'' were matched to their corresponding experimental values. Calculated values of aewere matched to experimental values of tL according to Eq. (27). Assumed values of n at each wavelength were checked for adherence to Eq. (28). A solution was obtained when all these conditions were met simultaneously for the same assumed particle size distribution (d3? and dmp/d32) at both wavelengths.