Caustic Corrosion Failure of Back Wall Riser Tube in a High-Pressure Boiler

Author:

Mobin M.,Malik A. U.

Abstract

Abstract A back wall riser tube in a high pressure boiler failed, interrupting operations in a cogeneration plant. The failure occurred in a tube facing the furnace, causing eight ruptured openings over a 1.8 m section. The investigation consisted of an on-site visual inspection, nondestructive testing, energy dispersive x-ray analysis, and inductively coupled plasma mass spectrometry. The tube was made from SA 210A1 carbon steel that had been compromised by wall thinning and the accumulation of fire and water-side scale deposits. Investigators determined that the tube failed due to prolonged caustic attack that led to ruptures in areas of high stress. The escaping steam eroded the outer surface of the tube causing heavy loss of metal around the rupture points.

Publisher

ASM International

Reference9 articles.

1. Refinery boiler feed water systems: corrosion and control;Cotton;Mater. Perform.,2000

2. Serum and Saliva Cortisol Responses and Blood Lactate Accumulation during Incremental Exercise Testing

3. Boiler Tube Failure: Case Histories of Steam Blanketing and Under Deposit Corrosion;Hargrave;Mater. Perform.,1994