Affiliation:
1. Semiconductor Manufacturing International Corp., Shanghai, China
Abstract
Abstract
The corrosion phenomenon was found at the edge area of bond pad under OM images after dicing saw. Experiment showed that the corrosion was related with the feed speed of dicing saw. From SEM and OM results, there were some abnormal contaminations around the corrosive area. Auger and TEM with EDX system were used to characterize the corrosive region and the related Al pad corrosion mechanism was discussed. In this paper, Cu rich and O rich layers were identified by TEM and EDX, which could be induced by galvanic cell reaction.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Reducing non-stick on pad for wire bond: A review;Australian Journal of Mechanical Engineering;2012-01