Concordance of Proteinuria Examination Results using Dipstick Urine, Albumin-Creatinine Ratio, and Immunoassay in Diabetes Mellitus Type-2

Author:

Marihot Sibagariang Charles1,Royland Marpaung Ferdy2

Affiliation:

1. Clinical Pathology Specialization Programme, Department of Clinical Pathology Faculty of Medicine, Airlangga University-Dr. Soetomo Hospital, Surabaya, Indonesia.

2. Department of Clinical Pathology, Faculty of Medicine, Airlangga University, Dr. Soetomo Hospital, Surabaya, Indonesia.

Abstract

Periodic examination of proteinuria for DM patients is important for the prevention of diabetic nephropathy complications. The most commonly used methods for checking proteinuria today are urine dipstick, albumin-creatinine ratio, and immunoassays. To analyze the suitability of proteinuria examination using a urine Dipstick, Albumin-Creatinine Ratio, and immunoassay. An observational analytic study, cross sectional, conducted in July 2020 - October 2020 at the Dr. Soetomo Surabaya, using urine samples (n = 57) that met the inclusion and exclusion criterias. The suitability test was carried out between the AIM urine dipstick, urine sysmex dipstick, AIM immunoassay and the Sysmex UC 3500 AC Ratio which were analyzed by the Cohen's kappa test. Immunoassay detected the highest proteinuria in 85.96% of type 2 DM patients, followed by AC Ratio (68.42%), AIM Dipstick (52.6%), and Sysmex Dipstick (49.12%). There was a very strong agreement between the AIM Dipstick and the Sysmex Dipstick, κ = 0.86 (p<0.05), a weak agreement between AIM immunoassay examination and Sysmex AC ratio, κ = 0.37 (p<0.05). There is no agreement between the Sysmex urine disptick and AIM immunoassay. There is a low agreement between the AIM Dipstick and the Sysmex AC Ratio. The AIM immunoassay detected microalbuminuria in 10(55.6%) of 18 subjects with negative results on Sysmex. Most immunoassay examinations detect proteinuria in type 2 DM patients. It is advisable to screen proteinuria using an immunoassay examination in type 2 DM patients1. Immunoassay examination can be relied on in screening proteinuria in DM patients. The results showed a very strong agreement using the AIM and the Sysmex dipstick examination. However, there was a weak agreement between the immunoassay examination and the AC ratio.

Publisher

A and V Publications

Subject

Pharmacology (medical),Pharmacology, Toxicology and Pharmaceutics (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3