Quality control of fat fraction quantification in magnetic resonance imaging: A two-center phantom study

Author:

Panina Olga Yu.ORCID,Ignatyeva Varvara A.ORCID,Monakhova Alyona A.ORCID

Abstract

BACKGROUND: Assessment of quantitative parameters using magnetic resonance imaging (MRI) is a relevant trend. Fat fraction (FF) calculation provides new opportunities for accurate diagnosis and will replace invasive methods such as biopsy in the future. Quantification will enable reliable dynamic monitoring and assessment of drug therapy. However, radiologists and clinical specialists must be confident in the accuracy and reliability of the quantitative measures. AIM: To assess the accuracy of quantitative FF measurement using phantom simulation in the range of 0% to 60%. METHODS: Emulsions of the oil-in-water type were chosen to simulate the objects of the study. Concentrations of vegetable oil-based emulsions were presented in the range of 0% to 60%. Tubes containing the emulsions were placed in a cylindrical phantom. Scans were performed on an Optima, MR450w 1.5 Tesla (GE) tomograph in Lava Flex mode and on an Ingenia, 1.5 Tesla (Philips) tomograph in DIXON mode. FF was determined by formulas using images in In-phase and Out-phase based on signal characteristics (FF=[InOut]/2∙In∙100) and images weighted by Water and Fat data (FF=Fat/[Fat+water]∙100. RESULTS: The accuracy of the fat percentage measurement with the DIXON technique was identical to that of the Lava Flex. The data of the measured fat concentration were systematically overestimated in relation to the target values by an average of 57.6% with an average absolute difference of 17.2%. In addition, an irregular underestimation in the range of 20% to 40% was detected. CONCLUSIONS: Phantom simulation using direct oil-in-water emulsions allowed to control the performance of the Dixon sequences in quantifying the FF. For correct FF quantification, calculation from Water and Fat image data using the formula FF=Fat/(Fat+water)∙100 is preferable. Calculations based on In-phase and Out-phase images provide ambiguous results. The FF calculation in the Lava Flex and DIXON modes must be performed with a correction factor. The use of the phantom allows proper quality control and calibration of the MRI scanner and makes quantitative fat measurement widely available.

Publisher

ECO-Vector LLC

Subject

Automotive Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3