Influence of prosthesis – patient mismatch on long-term results in patients after aortic valve replacement with a biological prosthesis: retrospective single center study

Author:

Bazylev Vladlen V.ORCID,Tungusov Dmitriy S.ORCID,Babukov Ruslan M.ORCID,Bartosh Fedor L.ORCID,Mikulyak Artur I.ORCID,Levina Alena V.ORCID

Abstract

Background. Despite numerous studies, ambiguity remains at present regarding the impact of prosthesis-patient mismatch (PPM) on long-term outcomes after aortic valve (AV) replacement. Objective. This study evaluates the effect of PPM on long-term results in patients after AV replacement with a biological prosthesis. Material and methods. We retrospectively analyzed the data of 231 patients who underwent AV replacement with a biological prosthesis from 2010 to 2018 at the Penza Federal Center of Cardiovascular Surgery. Patients were implanted with the following biological prostheses: Medtronic Mosaic, Edwards PERIMOUNT, Biocor. Results. Moderate PPM was present in 131 patients (56%), and severe PPM in 1 patient (0.7%). The mean follow-up was 78.832 months. There were no significant differences in hospital mortality in patients with and without PPM, 4 (3%) and 3 (2,9%), respectively, p=0.9. In the long-term period, patients with PPM showed a slower regression of left ventricle (LV) mass and recovery of LV contractile function than patients without PPM, p=0.05. There was no significant difference in survival in the long-term follow-up period between patients with and without PPM long-term survival, 77.7% and 79%, respectively, p=0.6. Also, there were no significant differences in major adverse cardiac events and the freedom from adverse events was 90% and 91%; p=0.7. However, there was a tendency to more frequent hospitalization for chronic heart failure (CHF) exacerbation in the patient group with PPM than in those without PPM, 63.8% and 78%; HR 1.6; 95% CI 0.932.1, p=0.007. There was also a tendency for an increased biological valve structural degeneration in the group with PPM than in the group without PPM 76% and 87%, HR 1.4; 95% CI 1.43.1, p=0.01 According to the Cox regression, the overall postoperative mortality predictors were diabetes mellitus, vascular atherosclerosis HR 5; 95% CI 1.222, p=0.04 and HR 2.9; 95% CI 1.46.6, p=0.01 respectively. Predictors of the risk of hospitalization due to CHF exacerbation were previous myocardial infarction and PPM HR 0.4; 95% CI 0.20.9, p=0.04 and HR 1,5; 95% CI 0.92; p=0.005, respectively PPM HR 2; 95% CI 0.854.1, p=0.01. Conclusion. PPM is a common complication after AV replacement with a biological prosthesis. It is associated with a slower regression of LV mass, an increased risk of structural valve degeneration, and hospitalizations for exacerbated heart failure.

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3