Complex morphological and computed tomographic characteristics of vascularization of monochorionic diamniotic placentas with discordant weight of newborns

Author:

Frolova Ekaterina R.1ORCID,Tumanova Ulyana N.1ORCID,Sakalo Viktorya A.1ORCID,Gladkova Kristina A.1ORCID,Bychenko Vladimir G.1ORCID,Shchegolev Aleksandr I.1ORCID

Affiliation:

1. Research Center for Obstetrics, Gynecology and Perinatology

Abstract

BACKGROUND: Twin pregnancies compared to singleton pregnancies are characterized by a higher incidence of complications, particularly fetal growth retardation [1]. The main causes of discordance and fetal growth retardation are considered to be differences in the size of placental sites, leading to uneven metabolism of substances and blood, as well as disorders of fetal blood supply caused by vascular anastomoses in the placenta [2, 3]. Computed tomography with the administration of contrast agents can be an effective method to assess the angioarchitectonics and vascularization of the placenta after delivery [4]. AIM: The aim of this study is to conduct a comprehensive computed tomography and morphological evaluation of the vascularization features of monochorionic diamniotic placentas with discordant neonatal weight. MATERIALS AND METHODS: This study was based on the analysis of 33 monochorionic diamniotic placentas obtained after delivery at 27–37 weeks of gestation using the original complex computed tomography and morphological method of investigation [5]. Upon obtaining the placenta, its mass and size of placental sites were determined, as well as the type of attachment, length, diameter, and degree of cord tortuosity. Prior to the computed tomography examination, the umbilical cord and its major branches were cleared of blood clots. The placenta was then immersed in a 10% hypertonic sodium chloride solution and placed on hygroscopic material. Subsequently, contrast dye mixtures of varying colors and concentrations were gradually injected into the unpaired umbilical vein, followed by the umbilical arteries in a sequential manner. The contrast dye mixtures consisted of a water-soluble radiopaque contrast agent, iodixanol, in an aqueous solution of gouache dye. The concentration of the contrast agent in the mixture for injection into the umbilical arteries was 70%, while in the vein it was 15%. The first and second placentae were injected with red and yellow gouache dyes, respectively, into the arteries of the umbilical cord, while blue and green gouache dyes were used for the veins. Following each injection of the contrast dye mixture into the umbilical cord vessel, a visual assessment of the vessel’s branching was conducted, followed by computed tomography on a Toshiba Aquilion ONE 640 (Pediatric 0.5 software package according to the Abdomen Baby study protocol). The final stage involved a traditional macroscopic and microscopic examination of the placenta [6]. RESULTS: The study revealed that the mean value of birth weight discordance in twins was 22.7 ± 2.1%, while placental site discordance was 26.6 ± 5.0%. Vascular anastomoses were identified in 74.2% of twin placentas. Of these, 19 cases exhibited one anastomosis, three cases demonstrated two anastomoses, and one case exhibited five anastomoses. Arterio-arterial anastomoses were observed with greater frequency, while veno-venous and arteriovenous anastomoses were observed with less frequency. The average diameter was 3.7 ± 0.15 mm for arterio-arterial anastomoses, 4.2 ± 0.23 mm for arteriovenous anastomoses, and 4.6 ± 0.26 mm for venous-venous anastomoses. CONCLUSIONS: The use of the developed complex method, which includes computed tomography and the subsequent construction of three-dimensional models of placental vessels and spectral color maps, allows for the visualization of the features of placental vascularization, as well as the assessment of the type and size of existing anastomoses. In monochorionic diamniotic placentas with fetal discordance, a high frequency of abnormal umbilical cord attachment and vascular anastomoses was detected.

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3