Analysis of factors influencing the values of parameters of intraoperative flowmetry of coronary bypass grafts: retrospective single-center cross-sectional study

Author:

Bazylev Vladlen V.ORCID,Tungusov Dmitry S.ORCID,Senzhapov Ilgiz Ya.ORCID,Garanyan David N.ORCID,Mikulyаk Artur I.ORCID

Abstract

Оbjective. This study determines the factors that can affect the value of the parameters of intraoperative flowmetry of coronary bypass grafts. Material and methods. TTFM is a routine procedure accompanying coronary artery bypass grafting at the Federal State Budgetary Institution FTSSSh (Penza). This retrospective study included 995 consecutive patients who underwent isolated coronary artery bypass grafting of the left coronary artery. The exclusion criteria were damage to the right coronary artery bed, the emergency nature of the operation, and the combined pathology of the valvular apparatus. Patients who underwent anastomosis revision due to flowmetry parameters changes were also excluded from the study. Intraoperative assessment of coronary artery bypass grafts was performed using VeryQ and MiraQ MediStim flowmeters (Norway). Results. A total of 1733 arterial and 479 venous grafts were evaluated. The following factors influenced the average volumetric blood flow velocity value: composite shunting of the border stenosis increases the chance of reducing the volumetric blood flow below the threshold value by 1.841 times (OR=1.841; p=0.018), the combination of occlusion and borderline stenosis with composite shunting increases the chance of reducing the volumetric blood flow velocity by 3.91 times (OR=3.91; p=0.041), an increase in the diameter of the bypassed artery by 1.0 mm reduces the chance of a decrease in blood flow volume velocity by 53.7% (OR=0.423; p=0.05). Conclusion. The following factors influence the peripheral resistance index: coronary artery diameter (OR=0.21; p=0.001), degree of artery proximal stenosis (OR=0.987; p=0.034), the vascular wall condition (OR=2.25; p=0.05), type of conduit used (OR=0.298; p=0.002), and shunting method (OR=1.699; p=0.017). The following factors influence the mean volumetric blood flow velocity value: bypass method (OR=1.841; p=0.018), a combination of occlusion and borderline stenosis in composite bypass grafting (OR=3.91; p=0.041), and the bypassed artery diameter (OR=0.423; p=0.423; p=0.05).

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3