Microbiological Profile of the Implantation Zone under Different Mechanical Compression of Percutaneous Implants: Experimental Study

Author:

Stogov Maksim V.ORCID,Emanov Andrey A.ORCID,Goodovykh Natalia V.ORCID,Ovchinnikov Evgenyi N.ORCID,Tushina Natalia V.ORCID,Kuznetsov Viktor P.ORCID

Abstract

Background. Infection of percutaneous implants in patients with limb amputation is the most common complication. Aim of the study evaluation of the microflora in the implantation zone depending on the mechanical compression of the implant in conditions of its additional external fixation. Methods. The study was performed on 36 male rabbits. The tibia of all the rabbits was sawn at the border of the upper and middle parts. The medullary canal was reamed and a percutaneous implant was placed in the tibial stump. The segment and the implant were fixed with an Ilizarov apparatus. An additional compression device was installed in 30 animals. We used 5 compression modes, accordingly, 6 experimental groups were formed, 6 animals in each: group 1 without compression, group 2 compression on the implant with force of 0.053 N/mm2, group 3 compression on the implant with force of 0.105 N/mm2, group 4 compression on the implant with force of 0.158 N/mm2, group 5 compression on the implant with force of 0.211 N/mm2, group 6 compression on the implant with force of 0.263 N/mm2. The restraint was removed 6 weeks after implantation for a total follow-up of 26 weeks. The microflora of the place where the implant enters the skin (the implant / skin interface) was investigated, the level of blood leukocytes and the level of C-reactive protein in blood serum were determined. Results. On days 9-10 after implantation, significant differences in the microbial landscape were found at the site of the exit of the metal implant in animals of different groups. The largest number of strains was found in animals of groups 1, 5 and 6, the smallest in groups 2 and 3. The most frequently detected strains: S. saprophyticus and Enterococcus spp. It was found that the greatest statistically significant increase in the level of CRP in the blood serum was observed in animals of group 6. The level of leukocytes in animals of all groups did not change statistically significantly relative to preoperative values. Animals with better osseointegration (groups 2 and 3 no cases of implant loss) showed a minimal number of growing strains. Conclusions. The microbiological profile of the implantation zone of percutaneous implants changes depending on the amount of mechanical compression. The optimal mode is 0.053-0.105 N/mm2.

Publisher

ECO-Vector LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3