Mid-term Results of a Single-Stage Revision Anterior Cruciate Ligament Reconstruction: A Retrospective Analysis of 36 Cases

Author:

Gofer Anton S.ORCID,Alekperov Aleksandr A.ORCID,Gurazhev Mikhail B.ORCID,Avdeev Artem K.ORCID,Lukinov Vitaliy L.ORCID,Rubtsov Dmitriy V.ORCID,Pavlov Vitalii V.ORCID

Abstract

Background. Revision anterior cruciate ligament reconstruction is becoming more and more common in the knee surgery due to the annual increase in the number of primary anterior cruciate ligament reconstructions. Choosing the most suitable graft and determining the staging of the surgical treatment by preoperative assessment of the possibility of performing the most anatomical revision canals and their interposition with the primary canals are the main factors that influence treatment results. Aim of the study — comparative assessment of the results of using hamstring tendon and peroneus longus tendon autografts in a one-stage revision reconstruction of the anterior cruciate ligament. Methods. A retrospective analysis of the medical records of 36 patients who underwent revision anterior cruciate ligament reconstruction was performed. The patients were divided into two groups: in the patients of the study group (n = 19) a peroneus longus tendon (PLT) autograft was used, in the comparison group (n = 17) a hamstring tendon autograft (HT) was applied. Subjective and objective evaluation using the KOOS, IKDC, and Lysholm scales was performed, and position of the central entry points of the primary and revision canals was determined. There were no statistically significant differences in the objective assessment of the knee joint stability. Significantly better results of subjective assessment of the knee function according to the Lysholm and KOOS scales were obtained in the PLT group (p = 0.042 and p0.001, respectively). Position of revision canals corresponded to the standard values, but position of the femoral canal had a slight cranial and anterior displacement. It was also found that the PLT graft diameter was statistically significantly larger than the HT graft diameter (p0.001). Results. There were no statistically significant differences in the objective assessment of the knee joint stability. Significantly better results of subjective assessment of the knee function according to the Lysholm and KOOS scales were obtained in the PLT group (p = 0.042 and p0.001, respectively). Position of revision canals corresponded to the standard values, but position of the femoral canal had a slight cranial and anterior displacement. It was also found that the PLT graft diameter was statistically significantly larger than the HT graft diameter (p0.001). Conclusion. One-stage revision anterior cruciate ligament reconstruction is a safe and effective surgical procedure providing satisfactory objective and subjective clinical results. Use of peroneus longus tendon autograft allows to obtain better results in comparison with the hamstring tendon autograft.

Publisher

ECO-Vector LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3