Endovascular biometrics and engineering

Author:

Goloshchapov-Aksenov Roman S,Kicha Dmitry

Abstract

Aim. To study technical problems in the provision of endovascular care and to develop technological solutions for its improvement based on endovascular biometry. Methods. For the period 20152019 an expert analysis of the results of endovascular treatment of 1546 patients with chronic lower limb ischemia was performed, in which it was not possible to perform lower limb revascularization according to the standard method using a guide catheter, guidewire and balloon catheter. The expert group included 5 interventional radiologists who performed endovascular procedures. The results were assessed by the effectiveness of revascularization using the developed innovative technology from a system of catheters of various diameters and stiffness in comparison with the results of using standard endovascular technique. Calculation of adequate statistical indicators and their reliability were undertaken using Statistica software (version 6.0). Results. The critical and weak zones of the vascular bed were identified for the first time to substantiate the development of a technology for safe and effective endovascular revascularization. It has been established that technical difficulties in catheterization of vessels create the prevalence of atherosclerotic lesions and the limited technical capabilities of catheters and guidewires, which are manipulated under the conditions of increasing high friction with the vessel wall caused by tortuosity and atherosclerosis, the presence of weak and critical zones of the blood vessels, as well as a significant distance from the surgeon's hands to the area of medical manipulation, reaching 130200 cm. The developed innovative design from the catheter system ensured the effectiveness of endovascular lower limb revascularization in all patients (100%) using the femoral and brachial accesses compare to the standard technique of endovascular care (p 0.001). Conclusion. Endovascular instruments offered on the domestic market do not guarantee the effective completion of revascularization. The technology of vascular catheterization developed based on endovascular biometry ensures the successful completion of revascularization in 100% of cases.

Publisher

ECO-Vector LLC

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3