Intraocular Lymphoma in Dogs - Findings of Contrast Enhanced Ultrasound and ARFI Elastography

Author:

Madruga Gabriela MoraisORCID,Kniphoff da Cruz Igor CezarORCID,Carneiro Rafael KretzerORCID,Rossi Feliciano Marcus AntônioORCID,Maronez Marjury CristinaORCID,Uscategui Ricardo RamirezORCID,Morato Abreu Thais GuimarãesORCID,Perlmann EduardoORCID

Abstract

Background: Ocular lymphoma can affect the iris, conjunctiva, choroid, and retina and is mostly associated with multicentric disease. Elastography is an ultrasound technique that provides noninvasive, pain-free assessment of tissue stiffness. It has the ability to assess subtle changes throughout the organ as well as focal lesions. Microbubble contrast ultrasound enables the detection of incipient vascular flows, which are difficult to detect using traditional ultrasound methods. This study aimed to describe acoustic radiation force impulse (ARFI) elastography and microbubble contrast ultrasound findings in the eyes of two dogs diagnosed with intraocular T-cell lymphoma. Cases: Case 1. Physical examination revealed an exophytic mass in the left eye. Schirmer test revealed a secretion of 22 mm/min. Negative threat reflex, glare, direct pupillary light reflex, and consensual response were also noted. Biomicroscopy revealed hyperplasia of the third eyelid, overlapping with the affected eye. When the membrane was removed, moderate conjunctival hyperemia, mucoid secretion, and buphthalmia were observed. In addition, significant corneal edema was present, making it impossible to visualize the anterior chamber and perform fundus examination. The intraocular pressure, as measured with a rebound tonometer, was 39 mmHg. B-mode ultrasonography identified amorphous, hyperechoic, and heterogeneous structures throughout the anterior chamber, iris, and ciliary body. The elastogram showed that the mass had greenish tones and intermediate stiffness, and the mean SWV of the ciliary body and iris was 2 m/s. Contrast-enhanced ultrasound (CEUS) revealed vascularization of the neoformation region, with wash-in, peak, and wash-out values of 9.89 s, 24.56 s, and 107.87 s, respectively. Case 2. On physical examination, a change in the shape of the right pupil was observed. Schirmer test revealed a secretion of 20 mm/min, with negative threat, glare, and pupillary reflexes to direct and consensual light. Biomicroscopy revealed neoformation from 7 am to 11 am in the sclera, retina, and choroid complex, concomitant with dyscoria and conjunctival hyperemia. The intraocular pressure, as measured by rebound tonometry, was 33 mmHg. Fundoscopy revealed a mass in the temporal region and focal retinal detachment. No changes were observed in the contralateral eye. B-mode ultrasound revealed an increase in volume in the temporal region of the iris, ciliary body, and choroid with diffuse heterogeneity and partial retinal detachment. Elastographic examination revealed shades of green and yellow compatible with increased tissue stiffness. On quantitative examination, the mean SWVs of the ciliary body and iris were 3.14 m/s. On CEUS, the neoformation region presented wash-in, peak, and wash-out values of 8.67 s, 22.33 s, and 80.20 s. Discussion: B-mode ultrasonography established the tumor extent and evaluated echogenicity, verifying the involved ocular structures. The examination played an important role in the diagnosis as well as clinical management. ARFI elastography can detect small tissue changes, helping to define nodules and masses more reliably, in addition to allowing the verification of tissue stiffness. In both dogs, it was possible to verify that the masses presented greater rigidity than the adjacent tissues both qualitatively and quantitatively. In previous studies, it was found that cutaneous and breast lymphomas in humans were more rigid than adjacent tissues on elastography. This increase in rigidity and heterogeneity observed on elastograms can be explained by the extramedullary interactions of the matrix in T-cell lymphomas. Tumor growth is dependent on the blood supply, which was evaluated using CEUS in these cases. Furthermore, the ciliary body contrast filling times were longer than those described in normal dogs. Keywords: eye, surgery, diagnostic imaging, pain, veterinary ophthalmology, neoplasia. Título: Linfoma intraocular em cães - achados da ultrassonografia contrastada e elastografia  ARFI Descritores: olho, cirurgia, diagnóstico por imagem, dor, oftlamologia veterinária, neoplasia.

Publisher

Universidade Federal do Rio Grande do Sul

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3