Isometry of Potential Attachment Sites for the Iliotrochanteric Suture in Dogs: an ex vivo Study

Author:

Cintra Cristiane Alves,Dias Luís Gustavo Gosuen Gonçalves,Dias Fernanda Gosuen Gonçalves,Ferreira Danyelle Rayssa Cintra,Pereira Lucas De Freitas,Rocha Jessé Ribeiro,De Carvalho Leonardo Lamarca,Selmi André Luis

Abstract

Background: Coxofemoral luxation is the most common traumatic luxation in dogs and the iliotrochanteric suture is one of the surgical treatment options. The orthopedic suture aimed at surgically restoring joint movement should be employed in an isometric manner in order to maintain adequate tension throughout the arc of motion. This study aimed to determine the isometric points for the iliotrochanteric suture in dogs during the joint extension and flexion movements. This evaluation was performed both in the intact hip joint and in the luxation model, establishing the best combination, among the determined points, for the reestablishment of normal joint movement.Materials, Methods & Results: Radiographic analyses of 12 canine cadaveric hips, both intact and in craniodorsal luxation model, were performed in a neutral position, flexion at 50°, and extension at 150°. In the trochanteric segment, two parallel lines were drawn, creating the central vertical axis and the secondary vertical axis. Three points were then determined on each axis, from proximal to distal, corresponding to 25, 50, and 75% of the height of the axis, and were labelled as T1, T2, and T3 and T4, T5, and T6, respectively. In the iliac segment, a line perpendicular to the longitudinal axis of the ilium was drawn, and 25, 50, and 75% of this height corresponded to points I1, I2, and I3, respectively. The lengths between the points were measured, with the objective of evaluating which combination of points presented less variation in the joint positions. The central location of the iliac and trochanteric segments, determined respectively by I2 and T2, provided smaller variations during the maximal movements of hip flexion and extension.Discussion: The surgical techniques of iliotrochanteric suture target to maintain the internal rotation of the femoral head inside the acetabulum and abduction of the femur until the soft tissues have healed. The described techniques for the iliotrochanteric suture present a great anatomical variety in the arrangement of the anchor points of the suture. It is known that if during motion, the attachment sites move closer to one another, the suture will become lax and, if the attachment sites move away from one another, the suture will tighten. Therefore, the implantation in isometric sites assists in reducing the variation of the distance between the points of origin and insertion of the suture during joint movement, keeping the suture tension constant and allowing the functional recovery of the joint. This study demonstrates that there are some locations for the origin and insertion of an iliotrochanteric suture that are associated with less length change than others. I2-T2 combination is the point closest to isometry for the iliotrochanteric suture during hip extension and flexion, so that, T2 is the most central point of the greater trochanter, corresponding to 50% of the height of its central vertical axis, as well as I2, which corresponds to the most central point of the ilium, representing 50% of the height of the most caudal portion of its body. The isometric point found by us details the exact location of perforation in all aspects (height and length), both in the ilium and the trochanter. In addition, it is a personalized point created for each patient from its radiographic examination and taking into consideration its anatomical variations, so that there is no damage to the suture during hip extension and flexion movements.

Publisher

Universidade Federal do Rio Grande do Sul

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3