Clinical comparison between two stabilization methods in distal tibial angular deviation corrected by the CORA method

Author:

Dos Santos Malta Caio Afonso,Lopes Muzzi Leonardo Augusto,Pacheco Larissa Teixeira,Garcia Perez Neto Daniel Munhoz,Pires Vanessa Matos,De Andrade Caroline Ribeiro,Lázaro Muzzi Ruthnéia Aparecida

Abstract

Background: Angular deformity is characterized by the deviation of part of the bone that can occur in three different planes, frontal, sagittal and transverse. Trauma on physeal plates is the most common cause of angular deviations of the limbs in dogs. Currently the CORA (Center of Rotation of Angulation) methodology is the best way to evaluate and surgically correct these deformities. The objective of this study is to describe the surgical procedures performed to treat the uniapical valgus deviation affecting both tibial bones in a dog, comparing the outcomes of hybrid external skeletal fixator used in the right pelvic limb in relation to the locking plate used in the left pelvic limb.Case: A 10-month old Border Collie dog was attended at the University Veterinary Hospital with history of lameness and deviation of both pelvic limbs. In the orthopedic examination, it was possible to identify bilateral valgus deviation in the region of the tibio-tarsal joints and moderate lameness, with absence of pain or joint crepitation. Radiographic examination showed that the deformity was only uniapical in the frontal plane, affecting both tibial bones of the dog. Signs of osteoarthrosis were not observed and the preoperative examinations were within the normal limits for the species. The deformities were corrected in two surgical times starting with the procedure in the right tibia, which appeared to be clinically worse. Due to the fact that it was a bilateral affection and there was not a healthy pelvic limb to obtain the normal angles values of this dog, for planning according to the CORA methodology, the values of the tibial mechanical angles for dogs of similar size were taken from the literature. For surgical correction of the right tibia, a closed wedge osteotomy was performed following the second rule of Paley, with bone stabilization using type IB hybrid external skeletal fixator (ESF). The radiographic follow-up was done every 30 days postoperatively, however at 60 days the dog presented with severe lameness and the ESF had to be removed due to the breaking of one of the wires that composed the ring of the hybrid system. The limb continued to be treated by external bandages and total bone healing occurred at 210 days after surgery. Only after the complete recovery of the right limb, the left pelvic limb was operated and was also corrected by closed wedge osteotomy from the second Paley's rule. However, the bone stabilization was achieved with the use of a T-shaped locking plate. Radiographic follow-up was performed every 30 days postoperatively and at 60 days the osteotomy gap was already consolidated and the dog showed good weight bearing in the pelvic limbs without signs of lameness or pain.Discussion: Currently, it is indicated that bone deformities in small animals should be corrected using the CORA methodology. The hybrid ESF is one of the most commonly used fixation systems for bone stabilization after corrective osteotomies due to great versatility, however, the reported complication rates are relatively high. The locking plates with special shapes, such as the "T" plate used in this study, provide the stable fixation of osteotomies with limited bone stock, as they allow the introduction of larger number of screws per area. Thus, this latter type of implant becomes advantageous for the correction of bone deformities close to the joints. It is concluded that CORA methodology is really effective in the planning of corrective surgeries of angular deviations in dogs. In this case report, the resulting tibial angles after the surgical corrections were within the normal range for healthy dogs of similar size. However, the use of locking plate provided better results with early bone healing and fewer complications than the type IB hybrid ESF.

Publisher

Universidade Federal do Rio Grande do Sul

Subject

General Veterinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Treatment of a malunion of the tibia and fibula in a giant anteater (Myrmecophaga tridactyla);Arquivo Brasileiro de Medicina Veterinária e Zootecnia;2022-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司