Conventional vs. Advanced Echocardiographic Parameters for Predict Fluid Responsiveness in Healthy Dogs

Author:

Buba Lucina StephanyORCID,Muehlbauer Eloisa,Bentivóglio Costa Silva Vinícius,Folgearini Silveira MatheusORCID,Wolf Marcela,Pereira dos Santos JulioORCID,Duque Moreno Juan CarlosORCID,Gonçalves Sousa Marlos,Rodrigues Froes Tilde

Abstract

Background: Volume replacement is considered an essential component in the treatment of critically ill patients, but excess fluid administration can be as harmful as the lack of fluid therapy. Therefore, the volume replacement is only beneficial in patients deemed to be fluid responsive, that is, when the individual has an increase in their stroke volume after administration of a volume challenge. This study aim to assess whether conventional and advanced echocardiographic parameters for assessing left ventricular systolic function are able to predict fluid responsiveness in healthy spontaneously breathing dogs. The hypothesis was that some of these parameters would differ between responsive and non-responsive animals and could be used as a complementary measure for assessment of fluid responsiveness.Materials, Methods & Results: A prospective study was carried out in which 22 client-owned healthy dogs over 1 year of age that presented to the Veterinary Medical Teaching Hospital for elective neutering procedure were included. All dogs underwent conventional and advanced echocardiographic examination to obtain the left ventricular internal diameter in diastole normalized (LVIDDn), left ventricular internal diameter in systole normalized (LVIDSn), ejection fraction (EF) and shortening fraction (SF) according to the Teischholz methodology, global longitudinal strain (GLS) and tissue motion annular displacement (TMAD). There parameters were evaluated before and after administration of a volume challenge with 10 mL/kg lactate ringer intravenously for 20 min. Based on the variation in aortic velocity integral time, 31.82% of dogs were considered responsive and 68.18% were non-responsive to the volume challenge. For advanced echocardiography, TMAD indexed by body weight (mm/kg) > 0.89 (P = 0.004) and body surface area (mm/m2) >18.9 (P = 0.004) after volume challenge had the best area under the curve values (both 0.895) and smaller gray zone intervals (0.52 - 0.81 and 14.89 - 17.88) for the identification of responsive dogs. Although, TMAD (mm/kg and mm/m2) before volume challenge was also higher in the responsive dogs (P = 0.041 and P = 0.029). As for conventional echocardiography, the LVIDDn < 1.39 (P = 0.003) before volume challenge had the best area under the curve value (0.866) and the smallest gray zone interval (1.4 - 1.57) for the identification of responsive dogs. The GLS and the TMAD in milimeters (mm), percentage (%) and indexed by cubic root of weight (mm/∛kg) did not differ between the responsive and non-responsive dogs before and after volume challenge.Discussion: TMAD indexed by body weight (mm/kg) and body surface area (mm/m2) before and after volume challenge and the LVIDDn before volume challenge may be useful measures to complement the assessment of fluid responsiveness in spontaneously breathing dogs. This is the first study to use TMAD as a predictive parameter for fluid responsiveness in healthy, spontaneously breathing, dogs. Even it is an advanced echocardiographic technique, TMAD has advantages interms of execution time and the fact that it is less dependence on image quality or operator experience. It is possible that in the future such variables may form a useful part of the evaluation of fluid responsiveness in dogs. However, more studies are needed to better understand the applicability of these techniques, especially in dogs with hemodynamic changes. Keywords: canine, global longitudinal strain, stroke volume, tissue motion annular displacement, TMAD, VTI.

Publisher

Universidade Federal do Rio Grande do Sul

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3