Glucose trend prediction model based on improved wavelet transform and gated recurrent unit

Author:

Yang Tao12,Yang Qicheng12,Zhou Yibo3,Wen Chuanbiao2

Affiliation:

1. College of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu 610000, Sichuan, China

2. Xin-Huangpu Joint Innovation Institute of Chinese Medicine, Guangzhou 510000, Guangdong, China

3. Beijing Certificate Authority Co., Ltd., Beijing 100000, China

Abstract

<abstract> <p>Glucose trend prediction based on continuous glucose monitoring (CGM) data is a crucial step in the implementation of an artificial pancreas (AP). A glucose trend prediction model with high accuracy in real-time can greatly improve the glycemic control effect of the artificial pancreas and effectively prevent the occurrence of hyperglycemia and hypoglycemia. In this paper, we propose an improved wavelet transform threshold denoising algorithm for the non-linearity and non-smoothness of the original CGM data. By quantitatively comparing the mean square error (MSE) and signal-to-noise ratio (SNR) before and after the improvement, we prove that the improved wavelet transform threshold denoising algorithm can reduce the degree of distortion after the smoothing of CGM data and improve the extraction effect of CGM data features at the same time. Based on this finding, we propose a glucose trend prediction model (IWT-GRU) based on the improved wavelet transform threshold denoising algorithm and gated recurrent unit. We compared the root mean square error (RMSE), mean absolute percentage error (MAPE), and coefficient of determination ($ {\mathrm{R}}^{2} $) of Recurrent Neural Networks (RNN), Long Short-Term Memory (LSTM), Support vector regression (SVR), Gated Recurrent Unit (GRU) and IWT-GRU on the original CGM monitoring data of 80 patients for 7 consecutive days with different prediction horizon (PH). The results showed that the IWT-GRU model outperformed the other four models. At PH = 45 min, the RMSE was 0.5537 mmol/L, MAPE was 2.2147%, $ {\mathrm{R}}^{2} $ was 0.989 and the average runtime was only 37.2 seconds. Finally, we analyze the limitations of this study and provide an outlook on the future direction of blood glucose trend prediction.</p> </abstract>

Publisher

American Institute of Mathematical Sciences (AIMS)

Subject

Applied Mathematics,Computational Mathematics,General Agricultural and Biological Sciences,Modeling and Simulation,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3