Determination of the location of the needle entry point based on an improved pruning algorithm

Author:

Zhang Guangyuan1,Gao Xiaonan1,Zhu Zhenfang1,Zhou Fengyv2,Yu Dexin3

Affiliation:

1. School of Information Science and Electrical Engineering, Shan Dong Jiao Tong University, Jinan 250000, China

2. School of Control Science and Engineering, Shandong University, Jinan 250000, China

3. Department of Radiology, Qilu Hospital of Shandong University, Jinan 250000, China

Abstract

<abstract> <p>Since the emergence of new coronaviruses and their variant virus, a large number of medical resources around the world have been put into treatment. In this case, the purpose of this article is to develop a handback intravenous intelligence injection robot, which reduces the direct contact between medical staff and patients and reduces the risk of infection. The core technology of hand back intravenous intelligent robot is a handlet venous vessel detection and segmentation and the position of the needle point position decision. In this paper, an image processing algorithm based on U-Net improvement mechanism (AT-U-Net) is proposed for core technology. It is investigated using a self-built dorsal hand vein database and the results show that it performs well, with an F1-score of 93.91%. After the detection of a dorsal hand vein, this paper proposes a location decision method for the needle entry point based on an improved pruning algorithm (PT-Pruning). The extraction of the trunk line of the dorsal hand vein is realized through this algorithm. Considering the vascular cross-sectional area and bending of each vein injection point area, the optimal injection point of the dorsal hand vein is obtained via a comprehensive decision-making process. Using the self-built dorsal hand vein injection point database, the accuracy of the detection of the effective injection area reaches 96.73%. The accuracy for the detection of the injection area at the optimal needle entry point is 96.50%, which lays a foundation for subsequent mechanical automatic injection.</p> </abstract>

Publisher

American Institute of Mathematical Sciences (AIMS)

Subject

Applied Mathematics,Computational Mathematics,General Agricultural and Biological Sciences,Modeling and Simulation,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3