Evaluation of infrared thermography, arterial Doppler ultrasound, and Doppler echocardiography in healthy adult dogs exposed to a single session of Whole-body vibration at different frequencies

Author:

AGOSTİNHO Manuela1ORCID,RAHAL Sheila2ORCID,BONATELLİ Shayra1ORCID,ROSA Gustavo2ORCID,TSUNEMİ Miriam3ORCID,ZADRA Vivian4ORCID,MAMPRİM Maria Jaqueline2ORCID,TAKAHİRA Regina1ORCID,SOUZA Paulo2ORCID,SANTOS Ivan5ORCID

Affiliation:

1. São Paulo State University, (Unesp), School of Veterinary Medicine and Animal Science (FMVZ)

2. São Paulo State University (Unesp), School of Veterinary Medicine and Animal Science (FMVZ)

3. São Paulo State University (Unesp), Botucatu Bioscience Institute

4. Maringa State University

5. Rondônia Federal University. School of Veterinary Medicine, Rolim de Moura, Rondônia; São Paulo State University (Unesp), School of Veterinary Medicine and Animal Science (FMVZ)

Abstract

This study aimed to evaluate the infrared thermography, arterial Doppler ultrasound, and Doppler echocardiography in healthy adult dogs exposed to a single Whole-body vibration (WBV) at different frequencies. Sixteen (16) healthy crossbreed dogs males of ages from 1 to 5 years, and weighing 16.3 to 24.5 kg were enrolled in the study. The dogs were exposed to a single WBV session at frequencies of 30 Hz (5 min), 40 Hz (5 min), and 50 Hz (5 min) with intervals between each frequency exposure of 10 min. The cutaneous temperature, arterial Doppler ultrasound, and Doppler echocardiography were evaluated 10 min before the WBV session, between each frequency, and 1 min after the last frequency. The cutaneous temperature of the regions of the superficial gluteal muscle and biceps femoris muscle of both hind limbs was obtained with an infrared camera. Resistive indexes of carotid and femoral arteries were determined using Doppler ultrasound, and Doppler echocardiography was used to assess the end-systolic volume and end-diastolic volume, heart rate, aortic blood flow velocity, and pulmonary artery flow velocity. Complete blood count and serum biochemical (alanine aminotransferase, creatinine, and creatine phosphokinase) were evaluated at 10 min before and 60 min after the end of the WBV session. Statistically significant differences were not found in any of the variables among the time points. In conclusion, the protocol of increasing vibration frequencies (30, 40, and 50 Hz) at short-period WBV can be considered appropriate since no change occurred in the parameters evaluated.

Funder

State of São Paulo Research Foundation (FAPESP), and National Council for Scientific and Technological Development (CNPq).

Publisher

Veterinary Journal of Ankara University

Subject

General Veterinary,Animal Science and Zoology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3