Affiliation:
1. Ranbaxy Research Laboratories, Plot No. 20, Sector-18, Udyog Vihar Industrial Complex, Gurgaon-122001, Haryana, India.
Abstract
This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC) and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm), 5 μ, The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N) hydrochloric acid), base (1.0 N sodium hydroxide), oxidation (30% hydrogen peroxide), thermal (105°C), photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%), linearity (linearity of range about 70-130 μg/mL), ruggedness (Overall % RSD about 0.35%), stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min.) and robustness.
Subject
Medical Laboratory Technology,Biochemistry,Analytical Chemistry
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献