Acute Urinary Obstruction in a Tetraplegic Patient from Misplacement of Catheter in Urethra

Author:

Vaidyanathan Subramanian1,Singh Gurpreet2,Hughes Peter L.3,Soni Bakul M.1

Affiliation:

1. Regional Spinal Injuries Centre, Southport and Formby District General Hospital, Southport, UK.

2. Department of Urology, Southport and Formby District General Hospital, Southport, UK.

3. Department of Radiology, Southport and Formby District General Hospital, Southport, UK.

Abstract

A male tetraplegic patient attended accident and emergency with a blocked catheter; on removing the catheter, he passed bloody urine. After three unsuccessful attempts were made to insert a catheter by nursing staff, a junior doctor inserted a three-way Foley catheter with a 30-mL balloon but inflated the balloon with 10 mL of water to commence the bladder irrigation. The creatinine level was mostly 19 μmol/L (range: 0–135 μmol/L) but increased to 46 μmol/L on day 7. Computerized tomography urogram revealed that the bilateral hydronephrosis with hydroureter was extended down to urinary bladder, the bladder was distended, prostatic urethra was dilated and filled with urine, and although the balloon of Foley catheter was not seen in the bladder, the tip of the catheter was seen lying in the urethra. Following the re-catheterization, the creatinine level decreased to 21 μmol/L. A follow-up ultrasound scan revealed no evidence of hydronephrosis in both kidneys. Flexible cystoscopy revealed inflamed bladder mucosa, catheter reaction, and tiny stones. There was no bladder tumor. This case report concludes that the cause of bilateral hydronephrosis, hydroureter, and distended bladder was inadequate drainage of urinary bladder as the Foley balloon that was under-filled slipped into the urethra resulting in an obstruction to urine flow. Urethral catheterization in tetraplegic patients should be performed by senior, experienced staff in order to avoid trauma and incorrect positioning. Tetraplegic subjects with decreased muscle mass have low creatinine level. Increase in creatinine level (>1.5 times the basal level) indicates acute kidney injury, although peak creatinine level may still be within laboratory reference range. While scanning the urinary tract of spinal cord injury patients with indwelling urinary catheter, if Foley balloon is not seen within the bladder, urethra should be scanned to locate the Foley balloon.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3