Reference Value Evaluation of Urine Sediment in Indonesian Adult Population Using Automated Urine Analyzer

Author:

Tomatala Eirene Jaquelene,Sumarpo Anton,Susanti Hani

Abstract

Locally established clinical laboratory reference value are required to interpret laboratory test results for screening, diagnosis, prognosis, determining retest criteria or as microscopic confirmation. The objective of this study is to establish urine sediments reference value by using automated urine flow cytometry, investigating erythrocyte, leukocyte, epithelial cells, types of epithelial cells, bacteria, casts, pathologic casts, crystals, yeast, sperm, and mucus in Indonesian population using Sysmex UF-4000. A cross sectional study was conducted in October 2018 – April 2019 at R. Said Sukanto National Police Hospital in Jakarta. The study involved 240 participants comprised of clinically healthy 120 males and 120 females aged 18-65, with normal urine chemistry, hematology, blood glucose, liver function (AST, ALT), and renal function (urea, creatinine). The reference value was reported in microliter (μL) or in High Performance Field (HPF) or Low Performance Field (LPF). Mann-Whitney test through MedCalc software was used to test significant differences with p value <0.05. This study observed significant differences between males and females in erythrocyte, epithelial cells, epithelial cell variety, bacteria, pathologic casts, and yeast”which are evidently higher in female patients. However, the mucus in LPF levels is found to be higher in male patients instead of the female, disparate than current reference value. Therefore, the reference value results were separated between the two groups in those aspects, whereas the results of other urine sediment characteristics studied were combined. As most reference value obtained are still within range of existing references, reference value established with Sysmex UF-4000 can be useful.

Publisher

PDS Patklin

Subject

General Medicine

Reference23 articles.

1. Terajima S, Yokomizo H, Yagi A, Miura M, Amano C. Evaluation study for reference intervals of urine

2. sediments using UF-1000i in medical check-up population. Sysmex J Int, 2009; 19(1): 1-4.

3. Getachew B, Gebreyyohanes T, Gebrselassie G, Kelli K, Hagos H, et al. Community-based reference interval of selected clinical chemistry parameters among apparently healthy adolescents in Mekelle City, Tigrai, Northern Ethiopia. PLoS One, 2020; 1-12.

4. Establishing and using reference intervals review;Ozarka;Turk J Biochem,2020

5. Sysmex corporation. UF-5000/4000 products detail. Available from https://www.sysmex.com (accessed January 10, 2021).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3