Author:
Zakharchenko O.,Levenets V.,Lonin O.,Sokolov S.
Abstract
The material shows the results of using the Geant4 program to simulate the operation and capabilities of the SKIF stand when recording radiation K-series with detector the AXAS-D of stable iodine in activated carbon, which is used for air purification at the NPP. The radiation spectra obtained in different situations are shown: at the entrance and exit of the measuring installation; and their processing. The parameters of the registration system were obtained – efficiency and dependence on the thickness of the detector crystal.
Publisher
Problems of Atomic Science and Technology
Reference9 articles.
1. International Standards: ISO 18417. Iodine charcoal sorbents for nuclear facilities – Methods for defining sorption capacity index. 2017, 21 p.
2. D3803-91(2022) Standard Test Method for Nuclear Grade Activated Carbon // ASTM International. 2022, 18 р.
3. KTA 3601 (11/2017). Safety Standards of the Nuclear Safety Standards Commission (KTA). Ventilation Systems in Nuclear Power Plants. 2017, 23 p.
4. V.V. Levenets, A.Yu. Lonin, A.P. Omelnik, V.I. Sokolenko, A.O. Shchur. Comparative Assessment of the Sorption Properties of Carbon Filters Used in the Ventilation System of NPP, using 131I and 127I // Nuclear Physics and Atomic Energy. 2017, v. 18, N 1, p. 37-42.
5. J. Allison, K. Amako, J. Apostolakis, et al. Recent developments in Geant4 // Nucl. Instr. Methods. 2016, A 835, p. 186-225; DOI: 10.1016/j.nima.2016.06.125