Improvement of the technique of positioning the endocardial electrodes of the cardiac contractility modulation device in patients with CHF with reduced ejection fraction and atrial fibrillation

Author:

Safiullina Alfiya A.1ORCID,Uskach Tatiana M.1ORCID,Sapelnikov Oleg V.1ORCID,Saidova Marina A.1ORCID,Ansheles Alexey A.1ORCID,Sergienko Vladimir B.1ORCID,Amanatova Valeria A.1ORCID,Grishin Igor R.1ORCID,Cherkashin Dmitry I.1ORCID,Akchurin Renat S.1ORCID,Tereschenko Sergey N.1ORCID

Affiliation:

1. Chazov National Medical Research Center of Cardiology

Abstract

Aim. To evaluate the efficacy and safety of the advanced technique for positioning the endocardial electrodes of a cardiac contractility modulation (CCM) device. Materials and methods. The CCM system was implanted in 100 patients, of which 60 CCM electrodes were positioned in the most optimal zones of myocardial perfusion, in particular, in the zone of the minor focal-scar/fibrotic lesion (the Summed Rest Score of 0 to 1–2, the intensity of the radiopharmaceutical at least 30%), and in 40 patients according to the standard procedure. Before the implantation of the CCM system, 60 patients underwent tomography (S-SPECT) of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest to determine the most optimal electrode positioning zones and 100 patients underwent transthoracic echocardiography at baseline and after 12 months to assess the effectiveness of surgical treatment. Results. Improved ventricular electrode positioning technique is associated with the best reverse remodeling of the left ventricular myocardium, especially in patients with ischemic chronic heart failure, with less radiation exposure to the surgeon and the patient, and without electrode-related complications. Conclusion. At the preoperative stage, it is recommended to perform a synchronized single-photon emission computed tomography of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest before implantation of the CCM device to assess the presence of scar zones/myocardial fibrosis in the anterior and inferior septal regions of the interventricular septum of the left ventricle, followed by implantation of ventricular electrodes in the zone of the minor scar/fibrous lesion, which will allow to achieve optimal stimulation parameters, increase the effectiveness of CCM therapy, reduce the radiation exposure on medical personnel and the patient during surgery.

Publisher

Consilium Medicum

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3