Determination of the Optimal Volume of Programmed Intermittent Epidural Bolus When Combined With the Dural Puncture Epidural Technique for Labor Analgesia: A Random-Allocation Graded Dose-Response Study

Author:

Xiao Fei1,Yao Han-Qing1,Qian Jing1,Deng Jia-Li1,Xu Zheng-Fen1,Liu Lin1,Chen Xin-Zhong2

Affiliation:

1. Department of Anesthesia, Jiaxing Women and Children’s Hospital of Wenzhou Medical University, Jiaxing, China

2. Department of Anesthesia, Women’s Hospital, Zhejiang University School of Medicine, Hangzhou, China.

Abstract

BACKGROUND: The dural puncture epidural (DPE) and the programmed intermittent epidural bolus (PIEB) techniques are recent innovations for labor analgesia. The optimal volume of PIEB during traditional epidural analgesia has been investigated previously but it is unknown whether these findings are applicable to DPE. This study aimed to determine the optimal volume of PIEB for effective labor analgesia after initiation of analgesia using DPE. METHODS: Parturients requesting labor analgesia received dural puncture with a 25-gauge Whitacre spinal needle and then had analgesia initiated with 15 mL of ropivacaine 0.1% with sufentanil 0.5 μg/mL. Analgesia was maintained using the same solution delivered by PIEB with boluses given at a fixed interval of 40 minutes starting 1 hour after the completion of the initial epidural dose. Parturients were randomized to 1 of 4 PIEB volume groups: 6, 8, 10, or 12 mL. Effective analgesia was defined as no requirement for a patient-controlled or manual epidural bolus for 6 hours after the completion of the initial epidural dose or until full cervical dilation. The PIEB volumes for effective analgesia in 50% of parturients (EV50) and 90% of parturients (EV90) were determined using probit regression. RESULTS: The proportions of parturients with effective labor analgesia were 32%, 64%, 76%, and 96% in the 6-, 8-, 10-, and 12-mL groups, respectively. The estimated values for EV50 and EV90 were 7.1 (95% confidence interval [CI], 5.9−7.9) mL and 11.3 (95% CI, 9.9−15.2) mL, respectively. There were no differences in side effects, including hypotension, nausea and vomiting, and fetal heart rate (FHR) abnormalities among groups. CONCLUSION: Under the conditions of the study, after initiation of analgesia using DPE, the EV90 of PIEB for effective labor analgesia using ropivacaine 0.1% with sufentanil 0.5 μg/mL was approximately 11.3 mL.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3