Validation of a Novel Method for Noninvasive Mixed Venous Oxygen Saturation Monitoring in Anesthetized Children

Author:

Svedmyr Anders12,Steiner Kristoffer34,Andersson Andreas12,Sjöberg Gunnar34,Hallbäck Magnus5,Wallin Mats1,Lönnqvist Per-Arne12,Karlsson Jacob12

Affiliation:

1. Department of Physiology and Pharmacology (FYFA), C3, Eriksson I Lars, PA Lönnqvist Group, Section of Anesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden

2. Department of Pediatric Perioperative Medicine and Intensive Care, Karolinska University Hospital, Stockholm, Sweden

3. Department of Pediatric Cardiology, Karolinska University Hospital, Stockholm, Sweden

4. Department of Women’s and Children’s Health, Karolinska Institute, Stockholm, Sweden

5. Maquet Critical Care AB, Solna, Sweden.

Abstract

BACKGROUND: Mixed venous oxygen saturation (SvO2) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO2), against gold standard CO-oximetry. METHODS: Capno-SvO2 was compared to SvO2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO2, and a concordance rate was calculated to evaluate the ability of Capno-SvO2 to track change. RESULTS: Twenty-five procedures were included in the study. Capno-SvO2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9–14) and −5 percentage points (95% CI, −8 to −3), respectively. The concordance rate was 92% (95% CI, 89–96). CONCLUSIONS: In conclusion, this first clinical application of a novel concept for noninvasive SvO2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO2 generates absolute values and trending capacity in close agreement with the gold standard reference method.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3