Labor Analgesia Initiation With Dural Puncture Epidural Versus Conventional Epidural Techniques: A Randomized Biased-Coin Sequential Allocation Trial to Determine the Effective Dose for 90% of Patients of Bupivacaine

Author:

Maeda Ayumi1,Villela-Franyutti Diego1,Lumbreras-Marquez Mario I.12,Murthy Anarghya1,Fields Kara G.1,Justice Samuel1,Tsen Lawrence C.1

Affiliation:

1. Department of Anesthesiology, Perioperative and Pain Medicine, Brigham & Women’s Hospital, Harvard Medical School, Boston, Massachusetts

2. Universidad Panamericana School of Medicine, Mexico City, Mexico.

Abstract

BACKGROUND: The dural puncture epidural (DPE) technique has a faster onset, better sacral spread, and improved bilateral coverage when compared to the conventional epidural (EPL) technique. Whether these qualities translate into a lower bupivacaine dose to provide initial analgesia is unknown. We sought to determine the effective dose of bupivacaine to achieve initial (first 30 minutes) labor analgesia in 90% of patients (ED90) with the DPE and EPL techniques, using a biased-coin, sequential allocation method. METHODS: A total of 100 women of mixed parity with term, singleton gestation at ≤5 cm dilation with no major comorbidities were randomized to receive a DPE or an EPL technique. An experienced anesthesiologist performed these techniques and administered an allocated dose of plain bupivacaine diluted with isotonic sterile 0.9% saline to a total volume of 20 mL via the EPL catheter. Bupivacaine doses for each subject were determined by the response of the previous subject, using a biased-coin sequential allocation method, with success defined by a numeric rating scale (NRS) < 3 at 30 minutes. Outcome assessments were performed by an investigator blinded to the technique and bupivacaine dose. Sensory and motor blockade and maternal or fetal side effects were recorded every 5 minutes for the first 30 minutes. The ED90 of bupivacaine with each technique was estimated using centered isotonic regression. RESULTS: A total of 95 women were included in the final analysis. The ED90 of bupivacaine was estimated at 29.30 mg (90% confidence interval [CI], 28.55–31.56) with a DPE technique and 45.25 mg (90% CI, 42.80–52.03) with an EPL technique. CONCLUSIONS: Using a biased-coin, sequential allocation method, the DPE technique requires less bupivacaine to achieve effective initial analgesia (ED90) when compared to the EPL technique.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3