In Vitro Investigation of Insulin Dynamics During 4 Hours of Simulated Cardiopulmonary Bypass

Author:

Schweizer Thilo1,Nossen Caroline M.1,Galova Barbara2,Schild Christof3,Huber Markus1,Bally Lia4,Vogt Andreas1,Siepe Matthias2,Nagler Michael3,Fischer Kady1,Guensch Dominik P.1

Affiliation:

1. Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

2. Department of Cardiac Surgery, Inselspital, Bern University Hospital, University of Bern, Bern Switzerland

3. University Institute of Clinical Chemistry, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland

4. Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern Switzerland.

Abstract

BACKGROUND: Hyperglycemia is common in patients undergoing cardiovascular surgery with cardiopulmonary bypass. We hypothesize that intraoperative hyperglycemia may be, at least partially, attributable to insulin loss due to adhesion on artificial surfaces and/or degradation by hemolysis. Thus, our primary aim was to investigate the loss of insulin in 2 different isolated extracorporeal circulation circuits (ECCs), that is, a conventional ECC (cECC) with a roller pump, and a mini-ECC (MiECC) system with a centrifugal pump. The secondary aim was to assess and compare the relationship between changes in insulin concentration and the degree of hemolysis in our 2 ECC models. METHODS: Six cECC and 6 MiECC systems were primed with red packed blood cells and thawed fresh-frozen plasma (1:1). Four additional experiments were performed in cECC using only thawed fresh-frozen plasma. Human insulin (Actrapid) was added, targeting a plasma insulin concentration of 400 mU/L. Insulin concentration and hemolysis index were measured at baseline and hourly thereafter. The end points were the change in insulin level after 4 hours compared to baseline and hemolysis index after 4 hours. The insulin concentration and hemolysis index were analyzed by means of a saturated linear mixed-effect regression model with a random offset for each experiment to account for the repeated measure design of the study, resulting in mean estimates and 95% confidence intervals (CIs) of the primary end points as well as of pairwise contrasts with respect to ECC type. RESULTS: Insulin concentration decreased by 63% (95% CI, 48%–77%) in the MiECC and 92% (95% CI, 77%–106%) in the cECC system that contained red blood cells. Insulin loss was significantly higher in the cECC system compared to the MiECC (P = .022). In the cECC with only plasma, insulin did not significantly decrease (−4%; 95% CI, −21% to 14%). Hemolysis index in MiECC increased from 68 (95% CI, 46–91) to 76 (95% CI, 54–98) after 4 hours, in cECC from 81 (95% CI, 59–103) to 121 (95% CI, 99–143). Hemolysis index and percent change of insulin showed an excellent relationship (r = −0.99, P < .01). CONCLUSIONS: Our data showed that insulin levels substantially decreased during 4 hours of simulated cardiopulmonary bypass only in the ECC that contained hemoglobin. The decrease was more pronounced in the cECC, which also exhibited a greater degree of hemolysis. Our results suggest that insulin degradation by hemolysis products may be a stronger contributor to insulin loss than adhesion of insulin molecules to circuit surfaces.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3