Clinical Decision Support as a Prevention Tool for Medication Errors in the Operating Room: A Retrospective Cross-Sectional Study

Author:

Amici Lynda D.1,van Pelt Maria123,Mylott Laura1,Langlieb Marin2,Nanji Karen C.24

Affiliation:

1. Northeastern University School of Nursing, Boston, Massachusetts

2. Department of Anesthesia, Massachusetts General Hospital, Boston, Massachusetts

3. Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts

4. Department of Anesthesia, Harvard Medical School, Boston, Massachusetts.

Abstract

BACKGROUND: Medication errors in the operating room have high potential for patient harm. While electronic clinical decision support (CDS) software has been effective in preventing medication errors in many nonoperating room patient care areas, it is not yet widely used in operating rooms. The purpose of this study was to determine the percentage of self-reported intraoperative medication errors that could be prevented by CDS algorithms. METHODS: In this retrospective cross-sectional study, we obtained safety reports involving medication errors documented by anesthesia clinicians between August 2020 and August 2022 at a 1046-bed tertiary care academic medical center. Reviewers classified each medication error by its stage in the medication use process, error type, presence of an adverse medication event, and its associated severity and preventability by CDS. Informational gaps were corroborated by retrospective chart review and disagreements between reviewers were resolved by consensus. The primary outcome was the percentage of errors that were preventable by CDS. Secondary outcomes were preventability by CDS stratified by medication error type and severity. RESULTS: We received 127 safety reports involving 80 medication errors, and 76/80 (95%) of the errors were classified as preventable by CDS. Certain error types were more likely to be preventable by CDS than others (P < .001). The most likely error types to be preventable by CDS were wrong medication (N = 36, 100% rated as preventable), wrong dose (N = 30, 100% rated as preventable), and documentation errors (N = 3, 100% rated as preventable). The least likely error type to be preventable by CDS was inadvertent bolus (N = 3, none rated as preventable). CONCLUSIONS: Ninety-five percent of self-reported medication errors in the operating room were classified as preventable by CDS. Future research should include a randomized controlled trial to assess medication error rates and types with and without the use of CDS.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference38 articles.

1. The call for standardizing safer drug labeling methods.

2. Perioperative Patient Safety Priorities: Medication Safety.,2024

3. Statement on labeling of pharmaceuticals for use in anesthesiology.

4. How can we tell how “smart” our infusion pumps are?

5. Preventable medication harm across health care settings: a systematic review and meta-analysis.;Hodkinson;BMC Med,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3