The Incidence and Predictors of Failed Spinal Anesthesia After Intrathecal Injection of Local Anesthetic for Cesarean Delivery: A Single-Center, 9-Year Retrospective Review

Author:

Jin Sherry Y.12,Munro Allana1,Aidemouni Milia1,McKeen Dolores M.13,Uppal Vishal1

Affiliation:

1. Department of Anesthesia, Dalhousie University and IWK Health Centre, Halifax, Nova Scotia, Canada

2. Humber River Hospital, Toronto, Ontario, Canada

3. Discipline of Anesthesia, Memorial University of Newfoundland, St. John’s, Newfoundland, Canada.

Abstract

BACKGROUND: The incidence of failed spinal anesthesia varies widely in the obstetric literature. Although many risk factors have been suggested, their relative predictive value is unknown. The primary objective of this retrospective cohort study was to determine the incidence of failed spinal anesthesia for cesarean deliveries at a tertiary care obstetric hospital, and its secondary objectives were to identify predictors of failed spinal anesthesia in the obstetrics population and quantify their relative importance in a predictive model for failure. METHODS: With local institutional ethics committee approval, a retrospective review of our hospital database identified the incidence of failed spinal anesthesia for 5361 cesarean deliveries between 2010 and 2019. We performed a multivariable analysis to assess the association of predictors with failure and a dominance analysis to assess the importance of each predictor. RESULTS: The incidence of failed spinal anesthesia requiring an alternative anesthetic was 2.1%, with conversion to general anesthesia occurring in 0.7% of surgeries. Supplemental analgesia or sedation was provided to an additional 2.0% of women. The most important predictors of a failed spinal anesthetic were previous cesarean delivery (odds ratio [OR], 11.33; 95% confidence interval [CI], 7.09–18.20; P < .001), concomitant tubal ligation (OR, 8.23; 95% CI, 3.12–19.20; P < .001), lower body mass index (BMI) (kg·m−2, OR, 0.94; 95% CI, 0.90–0.98; P = .005), and longer surgery duration (minutes, OR, 1.02; 95% CI, 1.01–1.03; P = .006). Previous cesarean delivery was the most significant risk factor, contributing to 9.6% of the total 17% variance predicted by all predictors examined. CONCLUSIONS: Spinal anesthesia failed to provide a pain-free surgery in 4.1% of our cesarean deliveries. Previous cesarean delivery was the most important predictor of spinal failure. Other important predictors included tubal ligation, lower BMI, and longer surgery duration.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3