Direct Comparison of Peak Bulk Flow Rate of Programmable Intermittent Epidural Bolus and Manual Epidural Bolus Using a Closed-End Multiorifice Catheter: An Experimental Study

Author:

Younger Joshua D.1,Faryami Ahmad2,Prasad Monica3,Viar Daniel4,Menkara Adam2,Tang Amy5,Harris Carolyn A.6

Affiliation:

1. Department of Anesthesiology, Pain Management, and Perioperative Medicine, Henry Ford Health, Detroit, Michigan

2. Department of Biomedical Engineering, Wayne State University, Detroit, Michigan

3. Department of Medical Education, Wayne State University School of Medicine, Detroit, Michigan

4. Department of Computer Science and Engineering, University of Toledo, Toledo, Ohio

5. Department of Public Health Science, Henry Ford Health, Detroit, Michigan

6. Department of Chemical Engineering and Materials Science, Wayne State University, Detroit, Michigan.

Abstract

BACKGROUND: The programmable intermittent epidural bolus (PIEB) has been popularized as the optimal delivery technique for labor analgesia. Suggested advantages of this method are less local anesthetic consumption, improved maternal satisfaction, potentially shorter duration of labor, and decreased workload requirements for the anesthesia providers. However, a manual bolus is still routinely used for breakthrough pain when the PIEB is underperforming. METHODS: We conducted a laboratory-based study to quantify the flow through a multiorifice epidural catheter using the PIEB setting on an epidural pump compared to the manual epidural bolus. Four syringe volumes, 3, 5, 10, and 20 mL, were selected for this experiment. The flow in a manual bolus was also studied with and without the presence of an epidural catheter filter. A generalized estimating equation analysis was done to compare data between the groups. RESULTS: Regardless of the syringe size, there was a several-fold increase in flow when a manual bolus was used compared to a pump-administered dose, with the highest difference in the peak flow rate observed in 3-mL boluses with up to a 12-fold difference, while the difference was, at most, 7-fold in 5-mL and 10-mL boluses. Manual boluses without a filter achieve a mean peak flow rate higher than manual boluses with a filter. CONCLUSIONS: Our study found that manual boluses produced a higher flow rate compared to the CADD-Solis epidural pump (Smiths Medical). This study also found that the placement of a particulate filter reduces the flow rates generated while bolusing. Bulk flow rate is directly correlated with induced pressure and solution spread. Because higher bolus pressure has been shown to provide a more efficient distribution of local anesthetic and more efficient pain relief, these results may have impactful clinical significance and will pave the way for future studies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3